Occupational Health and Safety Regulation, B.C. Reg. 296/97
Schedule 16-B
Schedule 16-B
Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, Schedule 16-B · last amended September 1, 2027 · read from BC Laws on November 17, 2026
The text
Schedule 16-B
[en. B.C. Reg. 139/2021, App. D, s. 9.]
(section 16.33)
WORKSAFEBC G603 STANDARD —
HEAVY DUTY GUARDS FOR WINDOWS 1
(1) This standard describes minimum requirements for the design of heavy duty guards (see Figure 1) for front, side and rear windows in mobile equipment where the operator is exposed to hazards of intruding or flying objects, such as snapped or whipping cables, logs and tree limbs, falling rocks or concrete, and loose debris.
(2) In this standard:
“grid element” means a vertical or horizontal member of a heavy duty guard inside the framework;
“HSS” means hollow structural section.
(3) In this standard, common industry practices are followed in expressing numerical measurements. 2
(1) A heavy duty guard must be able to protect the operator from one or more objects imparting an absorbed kinetic energy level of 11 526 joules (8 500 foot-pounds).
(2) When steel is used, a heavy duty guard must provide protection for the entire surface area of the window and must be positioned as follows:
(a) to allow for window cleaning, at least 10 cm (4 in) away from the exterior face of the window;
(b) to prevent side intrusion, not more than 20 cm (8 in) away from the exterior face of the window.
(3) When steel is used for a heavy duty guard, it must be suitable for cold temperatures as meeting the requirements of the standard CAN/CSA-M3471-05 (R2015) — Earth-Moving Machinery — Roll-Over Protective Structures — Laboratory Tests and Performance Requirements (Adopted ISO 3471:1994, first edition, 1994-02-01), which may be satisfied by using steel that is equivalent to ASTM A36, CSA G40.21 33G, 44W for plates, bars and angles and CSA G40.21 50W for HSS.
(4) The exterior frame of a steel heavy duty guard must be secured to the structural parts of the cab, which must be adequately designed and constructed to resist the impact loads imposed by the guard.
(5) The minimum edge beam size of a steel heavy duty guard must not be less than HSS 2.5 in x 1.5 in x 0.125 in.
(6) Gusset plates must be incorporated into each corner of a steel heavy duty guard if the length of an edge beam of the exterior frame exceeds 3 ft.
(7) Each grid opening in a steel heavy duty guard must not be greater than 20 cm x 20 cm (8 in x 8 in).
(8) The minimum size of the grid element in a steel heavy duty guard must be 1.9 cm (3/4 in) mild steel rod or a steel element of equivalent strength.
(9) The minimum mild steel rod diameter or steel element, as applicable, set out in subsection (8) must be proportionately increased if a steel heavy duty guard is longer or wider than 3 ft.
(10) Minimum visual interference to the operator must be one of the governing criteria in the design and positioning of the vertical members of a steel heavy duty guard.
(11) If steel flat bars are used as grid elements, they must be in a radiating pattern in line with the operator's line of sight.
(12) Effective September 1, 2021, wire rope is not permitted for construction of a new steel heavy duty guard.
(13) If nuts and bolts are used in the fabrication of a heavy duty guard, they must be Grade 8, at minimum.
(14) Materials with equal or better properties, including polycarbonate, may be used in place of those stipulated in this standard.
Figure 1
Typical Heavy Duty Guard
Read the Occupational Health and Safety Regulation on BC Laws ↗
Made under Workers Compensation Act, RSBC 2019, c. 1.