Occupational Health and Safety Regulation, B.C. Reg. 296/97

Schedule 16-C

Schedule 16-C

Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, Schedule 16-C · last amended September 1, 2027 · read from BC Laws on November 17, 2026

The text

Schedule 16-C [en. B.C. Reg. 139/2021, App. D, s. 9.] (section 16.33) WORKSAFEBC G604 STANDARD — LIGHT DUTY GUARDS FOR WINDOWS 1 (1) This standard describes minimum requirements for the design of light duty guards for front, side and rear windows in mobile equipment such as dozers, loaders, skidders, excavators and mulchers, where the operator is exposed to hazards of intruding or flying objects such as jill-pokes, individual brick-sized objects, rock or wood chips, and metal shrapnel. (2) In this standard, “HSS” means hollow structural section. (3) In this standard, common industry practices are followed in expressing numerical measurements. 2 (1) Light duty guards must each be able to protect the operator from one or more objects imparting the equivalent of a static load of 17 800 newtons (4 000 lbf) applied to an area of 64 cm2 (10 in2) anywhere on the guard. (2) If a window is made of tempered glass, a light duty guard must be made of polycarbonate or steel mesh. (3) If a window opening without glazing requires light duty guarding against metal shrapnel or other objects small enough to pass through steel mesh, the guard must be made of polycarbonate, whether or not there is already a steel mesh guard over the window opening. (4) Minimum visual interference to the operator must be one of the governing criteria in the design and positioning of the light duty guard. (5) On ROPS-equipped mobile equipment, a light duty guard may be attached to parts of the ROPS provided that the attachment does not adversely affect the performance of the ROPS and all the attachments must be clamped unless welding is permitted by the ROPS manufacturer or a professional engineer. 3 Polycarbonate guards (see Figure 1) must (a) be a minimum of 9.5 mm (3/8 in) thick, (b) not be drilled into or have been drilled, (c) overlap the window by 2.54 cm (1 in) all around, and (d) be mounted to the cab in accordance with Figure 1 and the cab must be adequately designed and constructed to resist the impact loads imposed by the guard. Figure 1 Mounting Detail for Light Duty Polycarbonate Guard 4 (1) Steel mesh guards (see Figure 2) must be suitable for cold temperatures as meeting the requirements of CAN/CSA-M3471-05 (R2015) — Earth-Moving Machinery — Roll-Over Protective Structures — Laboratory Tests and Performance Requirements (Adopted ISO 3471:1994, first edition, 1994-02-01), and may be satisfied by using steel that is equivalent to ASTM A36, CSA G40.21 33G, 44W for plates, bars and angles and CSA G40.21 50W for HSS. (2) A steel mesh guard must provide protection for the entire surface area of the window and must be positioned at least 10 cm (4 in) away from the exterior face of the window to allow for window cleaning. (3) The exterior frame of a steel mesh guard must be secured to the structural parts of the cab, which must be adequately designed and constructed to resist the impact loads imposed by the guard. (4) Minimum edge beam size of the exterior frame must be at least HSS 1 in x 1 in x 0.125 in. (5) Wherever there is an unsupported area of mesh greater than 0.5 sq m (5.4 sq ft), an interior intermediate stiffener must be installed to add rigidity and transfer loads from the mesh to the exterior frame and must be welded to the exterior frame. (6) The minimum size of intermediate stiffeners must be 1 in x 0.5 in flat steel bar. (7) Gusset plates must be incorporated if the length of an edge beam of the exterior frame exceeds 3 ft. (8) Each opening in the steel mesh must not be greater than 4.5 cm x 4.5 cm (1 3/4 in x 1 3/4 in), and the mesh must be made of a welded or woven wire of a minimum of 6 mm, which is welded to the exterior frame. (9) If nuts and bolts are used in the fabrication of the guard, they must be Grade 8, at minimum. (10) Effective September 1, 2021, wire rope is not permitted for use in a steel guard. Figure 2 Typical Light Duty Steel Mesh Guard
Read the Occupational Health and Safety Regulation on BC Laws ↗

Made under Workers Compensation Act, RSBC 2019, c. 1.