WORKSAFEBC G601 STANDARD —
HEAVY DUTY BACKSTOPS FOR LOGS AND ROCKS 1
(1) This standard describes minimum requirements for the design of a framework, grid elements and supports of a protective structure, referred to as a "backstop", over any exposed side of an operator's cab on cable log loaders and log yarders, which backstop is designed to protect the operator from head-on or side-on penetration into, or crushing of, the cab by large logs or rocks without excessive visual interference to the operator.
(2) In this standard:
“framework” means the main structural members of a backstop, consisting of horizontal and vertical edge beams;
“grid element” means a vertical or horizontal member of a backstop inside the framework;
“HSS” means hollow structural section;
“main frame” means the structural part of the undercarriage;
“supports” means the structural members connecting the backstop to the main frame, boom or substructure.
(3) In this standard, common industry practices are followed in expressing numerical measurements. 2
(1) A backstop must be built in accordance with one of the following:
(a) in a manner that is able to protect the operator's cab from penetration or crushing by a log that is 1 m (39.4 in) in diameter at the butt of the log and 12.8 m (42 ft) in length, weighing 4 439 kg (9 786 lbs), travelling 16 km/h (10 mph), or an equivalent combination of mass and speed of one or more rocks or more than one log, and imparting a total kinetic energy to the backstop of 44.2 kilojoules (32 600 foot-pounds);
(b) in accordance with the following minimum structural details, as applicable:
(i) for edge beams
(A) up to 3 ft long, HSS 4 in x 3 in x 1/4 in,
(B) over 3 ft and up to 6 ft long, HSS 6 in x 4 in x 1/4 in, or
(C) over 6 ft and up to 9 ft long, HSS 7 in x 5 in x 1/4 in;
(ii) for grid element sizes
(A) that are vertical grid elements, 1/2 in x 4 in ASTM A36 flat bar, or
(B) that are horizontal grid elements, 1 in diameter mild steel rod or steel elements of equivalent strength.
(2) A backstop must be positioned at least 10 cm (4 in) away from the glazed windows and exterior faces of the cab.
(3) Wire rope is not permitted for use as a grid element in a backstop.
(4) The framework must be secured to the main frame, boom or substructure of the mobile equipment.
(5) The supports, main frame, boom or substructure of the mobile equipment must be adequately designed and constructed to resist the impact loads imposed by the backstop.
(6) Gusset plates must be incorporated into each corner of the backstop if the length of an edge beam of the exterior frame exceeds 3 ft.
(7) Each grid opening must not be greater than 400 cm2 (62 in2).
(8) Minimum visual interference to the operator must be one of the governing criteria in the design and positioning of the vertical members of the guard.
(9) If flat bars are used as grid elements, they must be in a radiating pattern in line with the operator's line of sight (see Figures 1 and 2).
(10) Steel must be used for all parts of the backstop and must meet the performance requirements, including the performance requirements for cold temperatures, of the standard CAN/CSA-M3471-05 (R2015) — Earth-Moving Machinery — Roll-Over Protective Structures — Laboratory Tests and Performance Requirements (Adopted ISO 3471:1994, first edition, 1994-02-01). 3
(1) Subject to subsection (2),
(a) a backstop must be certified by the backstop manufacturer or a professional engineer as meeting this standard, and
(b) any addition, modification, welding or cutting on a backstop must be carried out in accordance with the instructions of, and the backstop must be recertified by, the backstop manufacturer or a professional engineer.
(2) Backstops manufactured prior to September 1, 2021 are exempt from subsection (1) (a) but not from any other part of this standard.
Figure 1
Mainframe-mounted Heavy Duty Backstop
Figure 2
Boom-mounted Heavy Duty Backstop