CONSTRUCTION PROJECTS, O. Reg. 213/91

Section 281

Cite as CONSTRUCTION PROJECTS, O. Reg. 213/91, s. 281 · current to November 11, 2026 · consolidated from April 20, 2026 · read from e-Laws on November 16, 2026

The text

(1) If a square or rectangular shaft is not more than six metres deep and has walls that are not more than 3.6 metres wide, the walls, (a) shall be fully sheathed with Number 1 Grade spruce planks that are at least fifty-one millimetres thick by 152 millimetres wide and are placed side by side; and (b) shall be supported by wales and struts. O. Reg. 213/91, s. 281 (1); O. Reg. 631/94, s. 11. (2) Wales and struts, (a) shall be made of number 1 structural grade spruce planks that are, (i) at least 152 millimetres by 152 millimetres, for a shaft that is not more than 2.7 metres deep, (ii) at least 203 millimetres by 203 millimetres, for a shaft that is more than 2.7 metres but not more than 4.3 metres deep, and (iii) at least 254 millimetres by 254 millimetres, for a shaft that is more than 4.3 metres but not more than six metres deep; (b) shall be spaced not more than 1.2 metres apart vertically; and (c) shall be adequately supported by vertical posts that extend to the bottom of the shaft. O. Reg. 213/91, s. 281 (2).
Read the CONSTRUCTION PROJECTS on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.