MINES AND MINING PLANTS, R.R.O. 1990, Reg. 854
Section 216
Cite as MINES AND MINING PLANTS, R.R.O. 1990, Reg. 854, s. 216 · current to November 11, 2026 · consolidated from July 1, 2025 · read from e-Laws on November 16, 2026
The text
(1) Except as prescribed in subsections (2), (3) and (4), the drum diameter to rope diameter ratio for a drum hoist shall be equal to or greater than,
(a) 60 to 1, where the nominal rope diameter is 25.4 millimetres or less; or
(b) 80 to 1, where the nominal rope diameter is greater than 25.4 millimetres. R.R.O. 1990, Reg. 854, s. 216 (1).
(2) The drum diameter to rope diameter ratio for a drum hoist in use for shaft sinking or for preliminary development work during shaft sinking shall be equal to or greater than,
(a) 48 to 1, where the nominal rope diameter is 25.4 millimetres or less; and
(b) 60 to 1, where the nominal rope diameter is greater than 25.4 millimetres. R.R.O. 1990, Reg. 854, s. 216 (2).
(3) The drum diameter to rope diameter ratio of a friction hoist shall be equal to or greater than,
(a) 80 to 1, for stranded ropes; and
(b) 100 to 1, for locked coil ropes. R.R.O. 1990, Reg. 854, s. 216 (3).
(4) Subsection (1) does not apply to a drum hoist where the drum diameter to rope diameter is,
(a) 54 to 1, where the nominal rope diameter is 25.4 millimetres or less; or
(b) 72 to 1, where the nominal rope diameter is greater than 25.4 millimetres,
so long as the drum hoist was manufactured prior to 1954 and the original load rating given by its manufacturer is not exceeded. R.R.O. 1990, Reg. 854, s. 216 (4).
Read the MINES AND MINING PLANTS on e-Laws ↗
Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.