Class 1 and 2 anaerobic digestion facilities, less than or equal to 500 kW

Cite as renewable energy approvals under Part V.0.1 of the Act, O. Reg. 359/09, s. 47 · current to November 11, 2026 · consolidated from July 28, 2026 · read from e-Laws on November 16, 2026

The text

(1) This section applies to a person who is constructing, installing or expanding a Class 1 or Class 2 anaerobic digestion facility that has a name plate capacity of less than or equal to 500 kW. O. Reg. 359/09, s. 47 (1). (2) No person shall construct, install or expand a facility mentioned in subsection (1) unless any biomass storage areas, farm material storage areas, digestate storage tanks, generating units, flares and anaerobic digesters of the facility are, (a) at least 250 metres from the nearest odour receptor; or (b) at least 125 metres from the nearest odour receptor, if, (i) the conditions set out in subsection (3) are met, or (ii) the facility is designed to minimize the discharge of odour to at least the same extent as if the conditions set out in subsection (3) were met. O. Reg. 359/09, s. 47 (2). (3) For the purposes of subclause (2) (b) (i), the following conditions must be met: 1. The facility must be designed to be equipped with an anaerobic digester that has a gas storage cover with a design permeability of less than 500 cm3/m2/day/bar. 2. If the facility is designed to be equipped with, i. any digestate storage tanks storing liquid digestate, the tanks storing liquid digestate with a total storage volume set out in Column 1 of Table 2 must be located at a distance from the nearest odour receptor that is equal to or greater than the distance set out opposite the volume in Column 2 of that Table, and ii. any digestate storage tanks storing solid digestate, the tanks storing solid digestate with a total storage volume set out in Column 1 of Table 3 must be located at a distance from the nearest odour receptor that is equal to or greater than the distance set out opposite the volume in Column 2 of that Table. 3. If the facility is designed to be equipped with flares, they must be located at a distance from the nearest odour receptor that is equal to or greater than the greatest distance at which any digestate storage tank is required to be located from the nearest odour receptor under paragraph 2. 4. The facility must be designed to operate with a minimum average monthly input of five per cent manure. O. Reg. 359/09, s. 47 (3). (4) Subsection (2) does not apply to a person mentioned in subsection (1) if, as part of the application for the issue of a renewable energy approval in respect of the renewable energy project, the applicant submits the following reports prepared in accordance with Table 1: 1. The emission summary and dispersion modelling report. 2. The noise study report. 3. The odour study report. O. Reg. 521/10, s. 27. (5) Subsection (2) does not apply in respect of an odour receptor that did not exist when the person proposing to construct, install or expand a facility mentioned in subsection (1) submitted an application for the issue of a renewable energy approval to the Director. O. Reg. 521/10, s. 27.
Read the renewable energy approvals under Part V.0.1 of the Act on e-Laws ↗

Made under Environmental Protection Act, R.S.O. 1990, c. E.19.