fire code, O. Reg. 213/07
Section 9.9.5.1
Cite as fire code, O. Reg. 213/07, s. 9.9.5.1 · current to November 11, 2026 · consolidated from January 1, 2026 · read from e-Laws on November 16, 2026
The text
(1) Access routes for fire fighting shall be provided in conformance with the requirements of Articles 3.2.5.5. to 3.2.5.7. of the 1994 Building Code.
(2) Sentence (1) does not apply where the building is sprinklered.
(3) In buildings not greater than 6 storeys in building height, existing access routes are deemed to comply with Sentence (1) if they
(a) have a clear width of at least 6 m,
(b) are capable of supporting the expected loads imposed by fire fighting equipment and surfaced with concrete, asphalt or other material that provides accessibility under all climatic conditions,
(c) are located not less than 3 m and not more than 15 m from the principal entrance, and
(d) are connected with a public thoroughfare.
(4) Despite Sentence (1), alternative methods may be approved where, in the opinion of the Chief Fire Official, they provide protection for life safety similar to the protection provided by compliance with Sentence (1).