fire code, O. Reg. 213/07

Section 9.9.2.2

Cite as fire code, O. Reg. 213/07, s. 9.9.2.2 · current to November 11, 2026 · consolidated from January 1, 2026 · read from e-Laws on November 16, 2026

The text

(1) Buildings shall comply with the requirements of Sentence (2), where the building is (a) not more than 1 storey in building height and not greater than 1200 m2 in building area, (b) not more than 2 storeys in building height and not greater than 900 m2 in building area, or (c) not more than 3 storeys in building height and not greater than 600 m2 in building area. (2) Floor assemblies and walls, columns and arches supporting floor assemblies shall have a fire-resistance rating not less than 30 min. (3) Where sleeping accommodation or meeting rooms are not provided in the basement, an existing fire separation between the first storey and basement is deemed to be in compliance with Sentence (2) where (a) the basement is sprinklered, (b) the building contains not more than four guest suites and provides sleeping accommodation for not more than 10 persons, and (i) interconnected smoke alarms are installed in conformance with Clause 9.9.4.1.(3)(c), (ii) doors connecting the basement and first storey have a fire-protection rating not less than 20 min and are equipped with self-closing and latching devices, and (iii) fire stopping of the wall space at the basement level is in conformance with Article 9.10.15.3. of the 1994 Building Code, or (c) the building is 1 storey in building height, not more than 600 m2 in building area, and (i) each guest suite has direct access to the outdoors by a door near ground level, (ii) doors connecting the basement and first storey have a fire-protection rating not less than 20 min and are equipped with self-closing and latching devices, (iii) fire stopping of the wall space at the basement level is in accordance with Article 9.10.15.3. of the 1994 Building Code, and (iv) an approved early warning system is installed consisting of fire detectors in the basement interconnected with alarm signalling devices that are audible in all guest suites. (4) The water supply for the sprinklers referred to in Clause (3)(a) may be taken from the domestic supply where the supply provides sufficient density for the largest fire compartment and where the supply is approved. (5) A building that is sprinklered is deemed to be in compliance with Sentence (2). Buildings up to 4 storeys
Read the fire code on e-Laws ↗

Made under Fire Protection and Prevention Act, 1997, S.O. 1997, c. 4.