fire code, O. Reg. 213/07

Section 4.3.2.1

Cite as fire code, O. Reg. 213/07, s. 4.3.2.1 · current to November 11, 2026 · consolidated from January 1, 2026 · read from e-Laws on November 16, 2026

The text

(1) Every outside aboveground storage tank for the storage of flammable liquids or combustible liquids shall be located in conformance with Sentences (2) to (5) with respect to a property line or a building on the same property. (2) Except as provided in Sentences (6) and (7), every aboveground storage tank containing stable liquids and having a working pressure of not more than 17 kPa (gauge) shall be separated from a property line or a building on the same property by distances (a) half those in Table 4.3.2.1., where protection is provided against fire or explosion in the tank in conformance with Sentence 4.3.2.5.(2), or (b) equal to those in Table 4.3.2.1., where protection referred to in Clause (a) is not provided. (3) Every aboveground storage tank containing unstable liquids and having a working pressure of not more than 17 kPa (gauge) shall be separated from a property line or a building on the same property by distances (a) equal to those in Table 4.3.2.1., but not less than 7.5 m, where protection is provided against fire or explosion in the tank in conformance with Sentence 4.3.2.5.(2), or (b) three times those in Table 4.3.2.1., but not less than 15 m, where protection referred to in Clause (a) is not provided. (4) Every aboveground storage tank containing boil-over liquids shall be separated from a property line or a building on the same property by distances (a) 0.75 times those in Table 4.3.2.1., where protection is provided against fire or explosion in the tank in conformance with Sentence 4.3.2.5.(2), or (b) equal to those in Table 4.3.2.1., where protection referred to in Clause (a) is not provided. (5) Where a storage tank containing stable liquids or unstable liquids has a working pressure greater than 17 kPa (gauge), the distances from a property line or a building on the same property shall be those specified in Sentences (2) and (3) multiplied by 1.5, but shall be not less than 7.5 m. (6) The minimum distance required in Sentence (2) from a storage tank containing only Class II or IIIA liquids to a building on the same property is permitted to be reduced to (a) 1.5 m provided the tank capacity is not more than 50000 L, or (b) zero provided the tank capacity is not more than 2500 L. (7) The minimum distance required in Sentence (2) is permitted to be waived provided the storage tank is in conformance with ULC-S655, “Aboveground Protected Tank Assemblies for Flammable and Combustible Liquids” and has a capacity of not more than 50000 L. (8) Where end failure of horizontal storage tanks may endanger adjacent property, the tanks shall be placed with the longitudinal axis parallel to such property. Table 4.3.2.1.
Read the fire code on e-Laws ↗

Made under Fire Protection and Prevention Act, 1997, S.O. 1997, c. 4.