Municipal Wastewater Regulation, B.C. Reg. 87/2012
Section 94
Municipal effluent quality requirements
Cite as Municipal Wastewater Regulation, B.C. Reg. 87/2012, s. 94 · last amended October 27, 2025 · read from BC Laws on November 17, 2026
The text
(1) A discharger must meet the applicable municipal effluent quality requirements as set out in this section and as listed in Table 9, 10 or 11.
(2) Subject to subsection (5), if the dilution ratio in respect of discharges to streams, rivers and estuaries is less than 100:1, a qualified professional conducting an environmental impact study must determine if municipal effluent quality must be better than that shown in Table 9, 10 or 11, as applicable.
(3) Subject to subsection (5), if the dilution ratio in respect of discharges to streams, rivers and estuaries used for recreational or domestic water extraction is less than 40:1, a person must not discharge unless all of the following requirements are met:
(a) the discharge meets advanced treatment requirements;
(b) no other discharge options are available;
(c) the discharge is authorized by a director.
(4) Subject to subsection (5), in respect of seasonal discharges or discharges to streams, rivers and estuaries that are not used for recreational or domestic water extraction, a director may approve the use of secondary treatment if there is a minimum dilution ratio of 20:1.
(5) Discharge is prohibited if the dilution ratio is less than 10:1.
(6) For discharges to marine waters having a maximum daily flow of less than 10 m3/d, a discharger must use a septic tank that meets the design requirements set out in section 39 [septic tanks].
(7) For all lagoon systems, the maximum TSS level is 60 mg/L.
Table 9 — Municipal Effluent Quality Requirements
If Maximum Daily Flow < 10 m3/d Municipal Effluent Quality Receiving Water Streams, Rivers and Estuaries
(Dilution Ratio) Lakes Marine Waters Column A
≥ 40:1 Column B
≥ 10:1 Column C
(surface area ≥ 100 ha) Column D
(open) Column E
(embayed) all flows: CBOD5 & TSS (mg/L) ≤ 45 ≤ 10 ≤ 45 n/a n/a
Table 10 — Municipal Effluent Quality Requirements
If Maximum Daily Flow ≥ 10 m3/d − < 50 m3/d Municipal Effluent Quality Receiving Water Streams, Rivers and Estuaries
(Dilution Ratio) Lakes Marine Waters Column A
≥ 40:1 Column B
≥ 10:1 Column C
(surface area ≥ 100 ha) Column D
(open) Column E
(embayed) all flows: CBOD5 & TSS (mg/L) ≤ 45 ≤ 10 ≤ 45 ≤ 130 ≤ 45
Table 11 — Municipal Effluent Quality Requirements
If Maximum Daily Flow > 50 m3/d Municipal Effluent Quality Receiving Water Streams, Rivers and Estuaries
(Dilution Ratio) Lakes Marine Waters Column A
≥ 40:1 Column B
≥ 10:1 Column C
(surface area ≥ 100 ha) Column D
(open) Column E
(embayed) daily flows
< 2x ADWF: CBOD5 & TSS (mg/L) ≤ 45 ≤ 10 ≤ 45 ≤ 45 ≤ 45 daily flows
< 2x ADWF: pH 6 − 9 6 − 9 6 − 9 6 − 9 6 − 9 daily flows
< 2x ADWF: total phosphorus (P), (mg/L) ≤ 1 ≤ 1 ≤ 1 n/a n/a daily flows
< 2x ADWF: ortho phosphate (P), (mg/L) ≤ 0.5 ≤ 0.5 ≤ 0.5 n/a n/a daily flows
≥ 2x ADWF: interim CBOD5 & TSS (mg/L) ≤ 130 ≤ 10 ≤ 130 ≤ 130 ≤ 130
Read the Municipal Wastewater Regulation on BC Laws ↗
Made under Environmental Management Act, SBC 2003, c. 53.