Municipal Wastewater Regulation, B.C. Reg. 87/2012

Section 36

Additional component and reliability requirements

Cite as Municipal Wastewater Regulation, B.C. Reg. 87/2012, s. 36 · last amended October 27, 2025 · read from BC Laws on November 17, 2026

The text

(1) In respect of diffuser requirements, a qualified professional must ensure that (a) diffusers must have multiple sections, and (b) the maximum oxygen transfer capability must not be measurably impaired with the largest section out of service. (2) In respect of blowers or mechanical aerators, a qualified professional must ensure that the remaining capacity with the largest unit out of service is able to achieve design maximum oxygen transfer. (3) In respect of holding basin requirements for a wastewater facility within reliability category I, a qualified professional must ensure that the treatment system has adequate capacity for all flows. (4) In respect of chemical flash mixer requirements for a wastewater facility within reliability category I and having only one basin, a qualified professional must provide for a backup system with at least 2 mixing devices, one of which may be installed. (5) In respect of package treatment plants for a wastewater facility within reliability category I, a qualified professional must provide for municipal effluent filtration in conjunction with discharging to ground.
Read the Municipal Wastewater Regulation on BC Laws ↗

Made under Environmental Management Act, SBC 2003, c. 53.