Geothermal Operations Regulation, B.C. Reg. 79/2017
Section 31
Casing requirements
Cite as Geothermal Operations Regulation, B.C. Reg. 79/2017, s. 31 · last amended September 1, 2023 · read from BC Laws on November 17, 2026
The text
(1) A well authorization holder must ensure that casing is designed so that it will not fail if subjected to the maximum loads and service conditions that can reasonably be anticipated during the expected service life of the well.
(2) A well authorization holder must use non-toxic drilling fluid during the drilling of a well until, in the opinion of a qualified professional, all usable groundwater has been isolated from the drilling fluid.
(3) A well authorization holder must ensure that surface casing for a well conforms to the following requirements:
(a) surface casing must be set in a competent formation at a depth sufficient to provide a competent anchor for anticipated well pressures;
(b) the annulus must be filled with cement to the surface.
(4) A well authorization holder must ensure that surface casing cement is not drilled out until sufficient compressive strength has been reached to allow the safe conduct of drilling operations.
(5) A well authorization holder must ensure that
(a) all reasonable measures are taken to cement all intermediate and production casing to the surface or a minimum of 200 m above the shoe of the previous casing string, and
(b) the cement is not drilled out until sufficient compressive strength has been reached to allow the safe conduct of drilling operations.
(6) If there is any reason to doubt the effectiveness of casing cementation, a well authorization holder must ensure that a survey is made to evaluate the cement integrity and that any necessary remedial measures are taken.
(7) On detection of a casing leak or failure, a well authorization holder must
(a) notify the regulator about the leak or failure without delay, and
(b) repair the leak without unreasonable delay.
(8) A well authorization holder must ensure that a well is configured so that the annulus between the surface casing and the next casing can freely vent.
Read the Geothermal Operations Regulation on BC Laws ↗
Made under Geothermal Resources Act, RSBC 1996, c. 171.