Geothermal Operations Regulation, B.C. Reg. 79/2017
Section 1
Definitions
Cite as Geothermal Operations Regulation, B.C. Reg. 79/2017, s. 1 · last amended September 1, 2023 · read from BC Laws on November 17, 2026
The text
In this regulation:
“abandon”, in relation to a well, means permanently to plug the well in accordance with Part 5 of the Drilling and Production Regulation, B.C. Reg. 282/2010;
“Act” means the Geothermal Resources Act;
“active”, in relation to a well, refers to a well that is used for any of the following:
(a) production, injection or disposal of fluids;
(b) drilling, completion or workover operations;
(c) monitoring reservoir pressure or obtaining other formation information;
“ASME B31.3” means the American Society of Mechanical Engineers standard ASME B31.3, Process Piping, as amended from time to time;
“barrier” means any fluid, plug or seal that prevents fluids from flowing unintentionally from a well or from a formation into another formation;
“completed”, in relation to a well or zone, means a well or zone that is physically able to permit
(a) the production of steam or fluids from the well or zone,
(b) the observation of the performance of a reservoir, or
(c) the injection or disposal of fluids;
“CSA Z662” means the Canadian Standards Association standard CSA Z662, Oil and Gas Pipeline Systems, as amended from time to time;
“inactive well” means a well that has not been abandoned but has not been active for 12 or more consecutive months;
“natural boundary” has the same meaning as in section 1 of the Land Act;
“official” means a person designated by the regulator to carry out a duty or exercise a power of the regulator under the Act;
“Peace River Block” has the same meaning as in the Petroleum and Natural Gas Grid Regulation, B.C. Reg. 536/2004;
“porous zones” include fractured zones;
“producing”, in relation to a well, means a completed well that has been placed on regular production;
“qualified professional” means a person who is licensed or registered as either a professional engineer or a professional geoscientist under the Professional Governance Act;
“quarter unit” has the same meaning as in the Petroleum and Natural Gas Grid Regulation;
“thermal gradient well” means a well drilled to obtain geotechnical information about a geothermal resource;
“unit” has the same meaning as in the Petroleum and Natural Gas Grid Regulation;
“unused equipment” means equipment on a location that
(a) is related to a decommissioned activity,
(b) is dismantled or partially dismantled to render the equipment inadequate for use,
(c) is in a derelict condition, or
(d) has been inactive for 10 years or longer;
“water body” means a natural water course or source of water supply, whether usually containing water or not, but does not include muskeg;
“water supply well” has the same meaning as in the Groundwater Protection Regulation, B.C. Reg. 39/2016;
“well control” means control of the movement of fluids into or from a well;
“well operation” means the operation of drilling, completing, recompleting, intervening, re-entering, carrying out a workover, suspending or abandoning a well;
“workover” means
(a) any operation that changes the configuration or producing characteristics of a well or zone,
(b) the installation or removal of equipment from a wellbore,
(c) stimulation operations, and
(d) maintenance operations.
Read the Geothermal Operations Regulation on BC Laws ↗
Made under Geothermal Resources Act, RSBC 1996, c. 171.