Geothermal Operations Regulation, B.C. Reg. 79/2017

Section 1

Definitions

Cite as Geothermal Operations Regulation, B.C. Reg. 79/2017, s. 1 · last amended September 1, 2023 · read from BC Laws on November 17, 2026

The text

In this regulation: “abandon”, in relation to a well, means permanently to plug the well in accordance with Part 5 of the Drilling and Production Regulation, B.C. Reg. 282/2010; “Act” means the Geothermal Resources Act; “active”, in relation to a well, refers to a well that is used for any of the following: (a) production, injection or disposal of fluids; (b) drilling, completion or workover operations; (c) monitoring reservoir pressure or obtaining other formation information; “ASME B31.3” means the American Society of Mechanical Engineers standard ASME B31.3, Process Piping, as amended from time to time; “barrier” means any fluid, plug or seal that prevents fluids from flowing unintentionally from a well or from a formation into another formation; “completed”, in relation to a well or zone, means a well or zone that is physically able to permit (a) the production of steam or fluids from the well or zone, (b) the observation of the performance of a reservoir, or (c) the injection or disposal of fluids; “CSA Z662” means the Canadian Standards Association standard CSA Z662, Oil and Gas Pipeline Systems, as amended from time to time; “inactive well” means a well that has not been abandoned but has not been active for 12 or more consecutive months; “natural boundary” has the same meaning as in section 1 of the Land Act; “official” means a person designated by the regulator to carry out a duty or exercise a power of the regulator under the Act; “Peace River Block” has the same meaning as in the Petroleum and Natural Gas Grid Regulation, B.C. Reg. 536/2004; “porous zones” include fractured zones; “producing”, in relation to a well, means a completed well that has been placed on regular production; “qualified professional” means a person who is licensed or registered as either a professional engineer or a professional geoscientist under the Professional Governance Act; “quarter unit” has the same meaning as in the Petroleum and Natural Gas Grid Regulation; “thermal gradient well” means a well drilled to obtain geotechnical information about a geothermal resource; “unit” has the same meaning as in the Petroleum and Natural Gas Grid Regulation; “unused equipment” means equipment on a location that (a) is related to a decommissioned activity, (b) is dismantled or partially dismantled to render the equipment inadequate for use, (c) is in a derelict condition, or (d) has been inactive for 10 years or longer; “water body” means a natural water course or source of water supply, whether usually containing water or not, but does not include muskeg; “water supply well” has the same meaning as in the Groundwater Protection Regulation, B.C. Reg. 39/2016; “well control” means control of the movement of fluids into or from a well; “well operation” means the operation of drilling, completing, recompleting, intervening, re-entering, carrying out a workover, suspending or abandoning a well; “workover” means (a) any operation that changes the configuration or producing characteristics of a well or zone, (b) the installation or removal of equipment from a wellbore, (c) stimulation operations, and (d) maintenance operations.
Read the Geothermal Operations Regulation on BC Laws ↗

Made under Geothermal Resources Act, RSBC 1996, c. 171.