(1) The person responsible for deactivating a water supply well, an injection well, a dewatering well or a remediation well must take the well pump out of operation by (a) shutting off the power supply to the well pump, or (b) removing or disconnecting the manual pump handle. (2) In the case of a flowing artesian well, the person responsible for deactivating the well must, in addition to complying with subsection (1), (a) prevent any flow of water back into the well, (b) stop any artesian flow through the casing, and (c) prevent any leakage of the artesian flow at the surface of the ground or into another aquifer. (3) The person responsible for deactivating a recharge well must install equipment that prevents water, contaminants and foreign matter from entering the well through the top of the well. (4) The person responsible for deactivating a monitoring well must take out of operation any equipment used for monitoring. (5) The person responsible for deactivating a closed-loop geoexchange well must take out of operation any equipment used for the geoexchange system.