Groundwater Protection Regulation, B.C. Reg. 39/2016
Section 23
Surface seal — water supply wells
Cite as Groundwater Protection Regulation, B.C. Reg. 39/2016, s. 23 · last amended December 1, 2022 · read from BC Laws on November 17, 2026
The text
(1) The person responsible for drilling a water supply well that has one or more casings must, in addition to meeting the requirements under section 22, complete the water supply well with a surface seal that is not less than 5 m in length, unless
(a) the depth of the water supply well is insufficient to have a surface seal length of 5 m, in which case the surface seal must be the greatest possible length up to 5 m, or
(b) the method of drilling the water supply well is by driving, in which case the surface seal must be not less than 1 m in length.
(2) In addition to the requirements set out in subsection (1), if bedrock is encountered at or within 5 m of the surface of the ground in the circumstances described in subsection (1), other than those circumstances described in paragraph (b) of that subsection, the surface seal must extend to a minimum depth of 1 m into competent bedrock, as shown in Figure 3 of Schedule 5.
Read the Groundwater Protection Regulation on BC Laws ↗
Made under Water Sustainability Act, SBC 2014, c. 15.