Groundwater Protection Regulation, B.C. Reg. 39/2016

Section 22

Surface seal — general requirements

Cite as Groundwater Protection Regulation, B.C. Reg. 39/2016, s. 22 · last amended December 1, 2022 · read from BC Laws on November 17, 2026

The text

(1) The person responsible for drilling a well that has one or more casings must complete the well with an effective, permanent and continuous surface seal, as shown in Figures 1 and 2 of Schedule 5. (2) A surface seal required under subsection (1) must be installed in accordance with the applicable requirements of this Part to prevent the entry of any foreign matter from the surface of the ground into the well or the aquifer, if any, penetrated by the well. (3) A surface seal required under subsection (1) must be (a) installed in all annular spaces of the well, (b) not less than 2.54 cm thick, including the wall thickness of any surface casing left permanently in place, and (c) not less than (i) 1 m in length, (ii) in the case of a water supply well, the length determined in accordance with section 23, or (iii) in the case of a closed-loop geoexchange well, the entire length of the ground loop, in accordance with section 25 [sealing closed-loop geoexchange wells]. (4) All openings in the production casing of a well, including, without limitation, joints, lifting holes, perforations and pitless adapter holes, that are within the length of the surface seal must be made watertight with non-toxic materials.
Read the Groundwater Protection Regulation on BC Laws ↗

Made under Water Sustainability Act, SBC 2014, c. 15.