(1) Written safe work procedures must be implemented to ensure the safety of workers lighting or operating a flare tip, flare stack or flare line. (2) Workers must be instructed in the application of the written work procedures required by subsection (1). (3) Before workers enter a flare system danger area where the installation is temporary and remote ignition of the pilot is not feasible (a) the flare line must be isolated, and (b) contaminants in the flare pit area must be less than 20% of the lower explosive limit. (4) The location of a flare pit or stack must not interfere with safe access to the work area. (5) If feasible, there must be a continuous ignition source before flow to a flare pit or stack occurs.