(1) If there is evidence or suspicion of a misfire after a blast is initiated, the blaster of record must not permit anyone to enter the danger area until the latest of the following: (a) if an electric detonator or electric igniter was used to initiate the blast, 15 minutes after the blaster of record disconnects the firing lines from the initiating device and shunts the lead wires; (b) if shock tube initiation was used to initiate the blast, 15 minutes after the blaster of record disconnects the lead-in line from the initiating device; (c) if an electronic detonator was used to initiate the blast, 30 minutes after the blaster of record disconnects the firing lines from the initiating device and shunts the lead wires; (d) if a safety fuse assembly was used to initiate the blast, 30 minutes after the estimated time of detonation; (e) the waiting period stated in the relevant manufacturer's instructions. (2) If there is evidence or suspicion of a misfire after a blast is initiated and a charge is known or suspected to be burning, the blaster of record must not permit anyone to enter the danger area until the later of the following: (a) one hour after the smoke clears; (b) the waiting period stated in the manufacturer's instructions.
Read the Occupational Health and Safety Regulation on BC Laws ↗