Occupational Health and Safety Regulation, B.C. Reg. 296/97
Section 16.33
Safeguards against objects, materials and tipovers
Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 16.33 · last amended September 1, 2027 · read from BC Laws on November 17, 2026
The text
(1) In this section and section 16.38, “tipover”, in respect of mobile equipment, means a roll about the longitudinal axis of up to 90°, or a rear or frontal pitchover about the transverse axis of up to 90°, which roll or pitchover results in the contact of the cab with a surface.
(2) Operators of mobile equipment, and any other riders of mobile equipment authorized by section 16.8, must be protected against any reasonably foreseeable hazards from falling, flying or intruding objects or materials, or tipovers, by means of cabs, windows, screens, grills, shields, deflectors, guards or structures on the mobile equipment that
(a) are designed and installed to provide an adequate view for the operator to safely use the mobile equipment, and
(b) meet the requirements of
(i) at least one of the following standards, if the mobile equipment is in the scope of the standard:
(A) CSA Standard B352.0-16, Rollover protective structures (ROPS), falling object protective structures (FOPS), operator protective structures (OPS), and tip-over protective structures (TOPS) for mobile machinery — General Canadian requirements;
(B) Society of Automotive Engineers (SAE) Recommended Practice J1356 MAR2013, Performance Criteria for Falling Object Guards for Excavators;
(C) SAE J2267 APR2007 Minimum Performance Criteria for Operator Front Protective Structures (OFPS) for Certain Equipment;
(D) ANSI/UL 752, Standard for Bullet-Resisting Equipment, 11th edition (with revisions up to and including December 11, 2015);
(E) WorkSafeBC G601 Standard — Heavy Duty Backstops for Logs and Rocks, set out in Schedule 16-A of this Part;
(F) WorkSafeBC G603 Standard — Heavy Duty Guards for Windows, set out in Schedule 16-B of this Part;
(G) WorkSafeBC G604 Standard — Light Duty Guards for Windows, set out in Schedule 16-C of this Part, or
(ii) an earlier version of at least one of the standards set out in subparagraph (i) (A) to (D), if the earlier version applied to the cabs, windows, screens, grills, shields, deflectors, guards or structures on the mobile equipment on the date of manufacture of the mobile equipment.
(3) A window on mobile equipment manufactured after February 1, 2002 or otherwise installed on mobile equipment after that date must be marked to identify the manufacturer, the standard to which the window conforms and, in the case of polycarbonate windows, the thickness and grade of material.
Read the Occupational Health and Safety Regulation on BC Laws ↗
Made under Workers Compensation Act, RSBC 2019, c. 1.