The minimum design factor based on breaking strength for wire rope on a mobile crane, unless otherwise specified by the crane or wire rope manufacturer, is
(a) for conventional wire rope
(i) 2.5 for pendant lines, 3 for boom hoist reeving and 3.5 for load lines, during erection, and
(ii) 3 for pendant lines, 3.5 for boom hoist reeving and 3.5 for load lines, at all times except during erection, and
(b) 5 for wire rope of nonrotating construction.