Occupational Health and Safety Regulation, B.C. Reg. 296/97
Section 10.10
Alternative procedures
Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 10.10 · last amended September 1, 2027 · read from BC Laws on November 17, 2026
The text
(1) If lockout of energy isolating devices as required by section 10.3 is not practicable,
(a) in the case of a power system as defined in Part 19 (Electrical Safety), the requirements of that Part must be followed,
(b) in the case of mobile equipment, the requirements of Part 16 must be followed,
(c) in the case of machinery or equipment designed and equipped with effective control system isolating devices, the devices must be locked out as required by sections 10.4 to 10.9, and 10.10 (2), and
(d) in an emergency, the energy isolating devices or control system devices must be effectively controlled to prevent inadvertent start up or hazardous energy release.
(2) Control system isolating devices and the procedures for using them must be approved in writing by the Board, and must be used by workers qualified and authorized to carry out the work.
Read the Occupational Health and Safety Regulation on BC Laws ↗
Made under Workers Compensation Act, RSBC 2019, c. 1.