In this Part:
“CAN/CSA C390-98” means CSA standard CAN/CSA C390-98 entitled Energy Efficiency Test Methods for Three-Phase Induction Motors;
“electric motor” means a machine that converts electrical power into rotational mechanical power and includes any such machine that is incorporated into any other product;
“enclosed motor” means an electric motor constructed in such a manner as to prevent the free exchange of air between the inside and outside of the case, but the case is not sufficiently enclosed to be termed airtight;
“explosion-proof construction” means an electric motor
(a) for which measures have been taken to prevent the possibility of the electric motor reaching excessive temperatures or producing arcs or sparks, or
(b) that is enclosed in a case that will withstand the explosion of any flammable gas or material that may enter the case, without being damaged and without transmitting an explosion outside of the case;
“general purpose electric motor” means
(a) an electric motor designed for usual service conditions, as described in section 44 (1), or
(b) an electric motor designed for unusual service conditions, as described in section 44 (2);
“integral gear assembly” means a product that is comprised of an electric motor and a gear mechanism that are combined in such a manner that
(a) the end bracket or mounting flange forms an integral part of both the electric motor and the gear mechanism, and
(b) if the electric motor and the gear mechanism are separated, only one of them remains intact;
“IP code” means an alpha numeric sequence indicating the degree of protection offered by an electric motor's enclosure from foreign object insertion and water ingress, as defined in section 5.2 of MG1;
“MG1” means NEMA Standards Publication MG1-2006, Motors and Generators;
“NEMA” means the National Electrical Manufacturers Association;
“open motor” means an electric motor with ventilating openings that permit passage of external cooling air over and around the windings of the electric motor.