Energy Efficiency Standards Regulation, B.C. Reg. 14/2015

Section 42

Minimum ballast efficacy factors for fluorescent lamp ballasts

Cite as Energy Efficiency Standards Regulation, B.C. Reg. 14/2015, s. 42 · last amended April 24, 2023 · read from BC Laws on November 17, 2026

The text

For the purposes of section 40 [additional efficiency standard for fluorescent lamp ballasts], the following table sets out the minimum ballast efficacy factors: Column 1 Application of Operation Column 2 Ballast Input Voltage Column 3 Total Nominal Lamp Wattage Column 4 Minimum Ballast Efficacy Factor (V) (W) (BEF) One F40T12 lamp Also for use on 40W/48T10/RS lamps 120 40 2.29 277 40 2.29 347 40 2.22 One F34T12 lamp 120 34 2.61 277 34 2.61 347 34 2.53 Two F40T12 lamps Also for use on 40W/48T10/RS lamps 120 80 1.17 277 80 1.17 347 80 1.12 Two F34T12 lamps 120 68 1.35 277 68 1.35 347 68 1.29 Two F96T12(IS) lamps Also for use on 60W/96T12/IS lamps 120 150 0.63 277 150 0.63 347 150 0.62 Two F96T12(ES) lamps 120 120 0.77 277 120 0.77 347 120 0.76 Two 110W F96T12HO lamps 120 220 0.390 277 220 0.390 347 220 0.380 Two F96T12HO(ES) lamps 120 190 0.42 277 190 0.42 347 190 0.41 Two F32T8 lamps 120 64 1.250 277 64 1.230 347 64 1.200
Read the Energy Efficiency Standards Regulation on BC Laws ↗

Made under Energy Efficiency Act, RSBC 1996, c. 114.