Energy Efficiency Standards Regulation, B.C. Reg. 14/2015

Section 44

General purpose electric motors

Cite as Energy Efficiency Standards Regulation, B.C. Reg. 14/2015, s. 44 · last amended April 24, 2023 · read from BC Laws on November 17, 2026

The text

(1) An electric motor designed for usual service conditions is an electric motor that (a) is designed for use under usual service conditions, as those conditions are described in MG1, (b) is not restricted to a particular application or type of application, and (c) meets both the standard operating requirements, as described in subsection (3), and the standard mechanical construction requirements, as described in subsection (4). (2) An electric motor designed for unusual service conditions is an electric motor that (a) is designed for (i) use under unusual service conditions, as those conditions are described in MG1, or (ii) a particular application or type of application, (b) may be used for most general purpose applications, and (c) meets either the standard operating requirements, as described in subsection (3), or the standard mechanical construction requirements, as described in subsection (4). (3) For the purposes of subsections (1) (c) and (2) (c), the standard operating requirements for an electric motor are as follows: (a) the electric motor is designed to standard horsepower and speed ratings in accordance with MG1 or IEC 60034-1:2004; (b) the electric motor is rated for continuous duty operation or duty type S1, as defined in IEC standard 60034-1:2004; (c) the electric motor has a rated voltage of not more than 600 volts AC; (d) the electric motor has a rated frequency of 50/60 Hz or 60 Hz; (e) the electric motor is a NEMA design A, B or C as defined by MG1, or IEC design H or N as defined in IEC standard 60034-12:2007; (f) the electric motor is designed to operate at a single speed. (4) For the purposes of subsections (1) (c) and (2) (c), the standard mechanical construction requirements for an electric motor are as follows: (a) the electric motor is a three-phase electric induction motor of a squirrel cage or cage type design; (b) the electric motor has open or enclosed construction, including explosion-proof construction; (c) the electric motor is constructed to NEMA T frame or U frame dimensions, or to equivalent IEC dimensions; (d) the electric motor has a 2-, 4-, 6- or 8-pole construction; (e) the electric motor is of foot-mounted construction or flange-mounted construction; (f) the electric motor has an IP code from 00 to 66.
Read the Energy Efficiency Standards Regulation on BC Laws ↗

Made under Energy Efficiency Act, RSBC 1996, c. 114.