Power Engineers, Boiler, Pressure Vessel and Refrigeration Safety Regulation, B.C. Reg. 104/2004

Section 2

Definitions and interpretation for this regulation

Cite as Power Engineers, Boiler, Pressure Vessel and Refrigeration Safety Regulation, B.C. Reg. 104/2004, s. 2 · last amended December 31, 2024 · read from BC Laws on November 17, 2026

The text

(1) In this regulation: “Act” means the Safety Standards Act; “antique show boiler” means a boiler forming part of a traction engine, threshing machine, steam locomotive, steam crane, donkey boiler plant or other plant of historical interest; “assistant chief engineer” means a power engineer who (a) is employed in a plant to assist the chief engineer, (b) holds a certificate of qualification not less than one class lower than that required to operate the plant as the chief engineer, and (c) is placed in charge of the plant when the chief engineer is absent from the plant; “assistant engineer” means the power engineer who is a person in charge of a part of a plant under the supervision of the shift engineer, and includes a maintenance engineer; “assistant shift engineer” means the power engineer who is under the immediate supervision of the shift engineer and assists the shift engineer with the supervision, operation or control of the plant; “boiler capacity” means the heat receiving surface of a boiler as specified in section 46; “brazing” has the same meaning as in CSA B51; “Canadian credential” has the same meaning as in section 1.1 of the Safety Standards General Regulation; “chemical recovery boiler” means a boiler that is capable of being fuelled by the black liquor that results from the Kraft pulp manufacturing process; “chief engineer” means a power engineer who is designated by the owner to be responsible for the operation and maintenance of a plant and who is responsible for ensuring that all regulated work in the plant is performed by appropriately qualified persons; “code” means the applicable code or standard referred to in the Schedule and adopted under this regulation; “control system” means an electronic, digital, pneumatic or other system that compares the process variable to a set point and automatically adjusts the input signal to the final control device; “CSA B51” means CSA Standard B51 Boiler, pressure vessel and pressure piping code; “CSA B52” means CSA Standard B52 Mechanical refrigeration code; “cushion tank” means a pressure vessel designed for installation in a heating plant or cooling system to provide a pneumatic cushion for the expansion or contraction of the fluid; “electric boiler” means a boiler heated by electricity; “engineering degree” means a degree in mechanical engineering that (a) is awarded following completion of an undergraduate engineering program accredited by the Canadian Engineering Accreditation Board, or (b) is otherwise acceptable to a provincial safety manager under this regulation; “expansible fluid” means any (a) vapour, (b) gaseous substance, or (c) liquid under pressure and at a temperature at which the liquid changes to a gas or vapour when the pressure is reduced to atmospheric pressure or when the temperature increases to ambient temperature; “fifth class plant” means (a) a power plant that exceeds 10 m2 of boiler capacity but does not exceed 50 m2 of boiler capacity, (b) a steam heating plant that exceeds 30 m2 of boiler capacity but does not exceed 300 m2 of boiler capacity, (c) a fluid heating plant that exceeds 150 m2 of boiler capacity but does not exceed 300 m2 of boiler capacity, (d) a low pressure thermal fluid plant that exceeds 150 m2 of boiler capacity but does not exceed 500 m2 of boiler capacity, (e) a low temperature, low pressure fluid plant that exceeds 300 m2 of boiler capacity but does not exceed 1 000 m2 of boiler capacity, or (f) an unfired plant that exceeds 150 m2 of boiler capacity but does not exceed 500 m2 of boiler capacity; “first class plant” means a power plant that exceeds 1 000 m2 of boiler capacity; “fitting” means a valve, gauge, regulating or controlling device, flange, pipe fitting, nozzle or other component that is attached to or forms part of a boiler, a pressure vessel, a pressure piping system or refrigeration equipment, but does not include pressure piping on a pressure vessel; “fluid heating plant” means a heating plant that heats fluid without vaporizing the fluid; “fourth class plant” means (a) a power plant that exceeds 50 m2 of boiler capacity but does not exceed 100 m2 of boiler capacity, (b) a heating plant that exceeds 300 m2 of boiler capacity, (c) a low pressure thermal fluid plant that exceeds 500 m2 of boiler capacity but does not exceed 1 500 m2 of boiler capacity, (d) a low temperature, low pressure fluid plant that exceeds 1 000 m2 of boiler capacity, or (e) an unfired plant that exceeds 500 m2 of boiler capacity but does not exceed 1 000 m2 of boiler capacity; “fuel cut-off device” means any device that has a manual reset and which will cut off fuel to the boiler burner when activated by a safety device; “general supervision status plant” means a plant for which the supervision of boilers, pressure vessels or refrigeration equipment is carried out in accordance with the requirements set out in section 55 and the technical and administrative specifications required by a provincial safety manager; “heat exchanger” means a vessel other than a boiler where heat is transferred, either directly or indirectly, from one medium to another; “heating plant” means (a) a boiler in which steam or other vapour may be generated at a pressure not exceeding 103 kPa, or (b) a boiler, other than a low-temperature, low-pressure boiler, in which water or an aqueous solution may be heated to a pressure not exceeding 1 100 kPa or a temperature not exceeding 121C; “heating surface” means the surface area of a boiler or pressure vessel that transfers heat, as determined under section 46; “high pressure steam plant” means an assembly of one or more boilers and includes ancillary equipment, the pressure piping system and a pressure plant, in which steam or vapour is generated at a pressure greater than 103 kPa; “high pressure thermal fluid plant” means an assembly of one or more thermal fluid boilers, but does not include a low pressure thermal fluid plant, and includes ancillary equipment, a pressure piping system and a pressure plant connected to an assembly of thermal fluid boilers; “high temperature, high pressure fluid plant” means an assembly of one or more boilers and includes ancillary equipment, a pressure piping system and a pressure plant, in which liquid is heated to a temperature greater than 121C or liquid is contained at a pressure greater than 1 100 kPa; “hydraulic or hydraulic purposes” means equipment that uses an incompressible fluid under pressure to generate and transmit power by converting energy from liquid pressure into mechanical energy; “ice facility plant” means a refrigeration plant used to make and maintain an artificial ice surface that is used for recreational purposes; “institution” means premises in which persons are confined to receive medical, charitable, educational or other care or treatment, or in which persons are held or detained; “interim power engineer's certificate of qualification” means a certificate issued under section 27 for a specific plant operation; “low pressure thermal fluid plant” means an assembly of one or more thermal fluid boilers that do not contain an expansible fluid and are protected with temperature control and safety devices that will not permit the boilers to continue to operate should the temperature rise to or above the vapour point of the contained thermal fluid at atmospheric pressure; “low temperature, low pressure fluid plant” means an assembly of one or more boilers, including ancillary equipment, that contain liquid and operate at a working pressure of 206 kPa or less and a temperature of 100C or less; “maintenance engineer” means a power engineer employed in the maintenance of a plant or associated auxiliary equipment; “marine engineer (motor) certificate of competency” means a credential issued by Transport Canada that provides evidence of an individual's level of competence with respect to marine motor systems; “oil well plant” means a high pressure steam plant that is used in the operation of a drilling rig or drilling operation; “person in charge” means the power engineer, operator or other individual present on the premises during a period of time, and designated by the owner or chief engineer to be responsible for and in control of the plant while it is in operation; “plant” means a power plant, heating plant, low temperature, low pressure fluid plant, low pressure thermal fluid plant, high pressure thermal fluid plant, refrigeration plant, oil well plant, unfired plant or pressure plant; “power engineer” means an individual who holds a final or interim certificate of qualification issued under section 13, 15, 17, 19, 23, 28 or 29; “power engineer trainee” means an individual who has received training and who assists in the operation of a plant but does not hold a certificate of qualification; “pressure” means gauge pressure; for the purposes of this regulation, 103 kPa is equivalent to 15 psi; “pressure plant” means an assembly of one or more pressure vessels and includes the engines, turbines, pressure piping systems, fittings, machinery and ancillary equipment of any kind used in connection with it or them; “pressure vessel plant” means a pressure plant that is not connected to a boiler plant or refrigeration plant; “pressure welder” means an individual who holds a pressure welder's certificate of qualification issued under section 42; “pressure welding” has the same meaning as "welding" in CSA B51; “professional engineer” means a person registered under the Professional Governance Act as a professional engineer; “public assembly occupancy premises” means premises in which persons congregate for civic, political, educational, religious, social or recreational purposes; “refrigerant” means a fluid that absorbs heat at a low temperature and pressure, with a change in state, and rejects it at a higher temperature and pressure; “refrigerant group” means the classification of one or more refrigerants into risk categories based on flammability and toxicity as defined in CSA B52; “refrigeration mechanic” means a person who holds any of the following: (a) a certificate of qualification, issued under the Skilled Trades BC Act, as a refrigeration and air conditioning mechanic; (b) an interprovincial red seal credential in the trade of refrigeration and air-conditioning mechanic; (c) a credential acceptable to a provincial safety manager; “refrigeration plant” means an assembly of refrigeration equipment and includes a pressure plant connected to it; “risk assessed status plant” means a plant for which the supervision of boilers, pressure vessels or refrigeration equipment is done in accordance with the requirements set out in section 56 and the technical and administrative specifications required by a provincial safety manager; “second class plant” means a power plant that exceeds 500 m2 of boiler capacity but does not exceed 1 000 m2 of boiler capacity; “shift engineer” means a power engineer who is a person in charge of a plant under the supervision of a chief engineer or one who is in charge of a plant when the chief engineer is absent; “steam heating plant” means a heating plant that generates steam or vapour; “thermal fluid” means fluids other than water or aqueous solutions that transfer heat with or without vaporization; “thermal fluid boiler” means a boiler, including fittings and appurtenances, in which a liquid hydrocarbon, hot oil or other thermal fluid other than water is heated with or without the occurrence of vaporization; “thermal fluid plant” means an assembly of one or more thermal fluid boilers and includes a pressure plant that is connected to the assembly of boilers; “third class plant” means (a) a power plant that exceeds 100 m2 of boiler capacity but does not exceed 500 m2 of boiler capacity, (b) a low pressure thermal fluid plant that exceeds 1 500 m2 of boiler capacity, or (c) an unfired plant that exceeds 1 000 m2 of boiler capacity; “unfired boiler” means a pressure vessel in which gas, steam or vapour may be generated for use external to the boiler by the application of heat resulting from something other than the combustion of fuel; “unfired plant” means a plant where heat from gas, steam or vapour or other heating medium is supplied to heat exchangers or used directly for the purpose of heating a facility or a process without combustion of a solid, liquid or gaseous fuel taking place on the premises; “water heater” means a vessel heated by the combustion of fuel, electricity or any other source for supplying potable hot water at pressures not exceeding 1 103 kPa and temperatures not exceeding 98.9C. (2) For the purposes of this regulation 1 square metre (m2) is equivalent to 10.76 square feet (ft2).
Read the Power Engineers, Boiler, Pressure Vessel and Refrigeration Safety Regulation on BC Laws ↗

Made under Safety Standards Act, SBC 2003, c. 39.