The text

(1) If the vapour control system is a vapour balancing system, the operator must ensure that the performance test referred to in section 87 covers the entire duration of the loading from a tank to a vehicle tank and the entire duration of the loading from a vehicle tank to a tank. (2) The test must include the following elements: (a) the use of a calibrated pressure gauge to monitor the pressure at the vapour outlet of the vehicle tank during loading; and (b) the use of visual, auditory or olfactory methods to monitor the pressure-vacuum vents on the vehicle tank and the tank to determine whether any of the vents open during loading. (3) During the test, loading must be performed in accordance with the operator’s standard operating procedures, involve vehicles typically used at the facility and be performed without modifications to enhance system performance for the purpose of the test.