The text
Based on the concentrations of NOx and O2 as measured in accordance with section 28, the NOx emission intensity, expressed in g/GJ, of the boiler or heater must be determined for each test run
(a) by means of the appropriate calculation of emissions by F-factors set out in Appendix A to the EC CEMS Code; or
(b) by the formula(NOx × 1.88 × 10-3 × Fg)/Σi(Fi × HHVi)whereNOxis the concentration of NOx ,Fgis the flow rate of the flue gas, expressed in m3/h at 25°C and 101.325 kPa, as measured in the test run and determined in accordance with EPA Method 4 or EC Method D and converted to its flow rate on a dry basis in accordance with EPA Method 2 or EC Method B,Fiis the flow rate of the ith fuel combusted, expressed for a solid or liquid fuel in a given unit/h and for a gaseous fuel in m3/h at 25°C and 101.325 kPa ,HHViis the higher heating value of the ith fuel combusted, being(a) for commercial grade natural gas, expressed in GJ/standard m3,(i) the higher heating value determined in accordance with any of the required HHV methods set out in section 22that apply, or(ii) 0.03793, and(b) in any other case, the higher heating value of that ith fuel determined in accordance with any of the required HHV methods set out in section 22 that apply, expressed in GJ/the given unit referred to in the description of Fi, andiis the ith fuel combusted, where i goes from 1 to n and n is the number of fuels combusted.
Read the Multi-Sector Air Pollutants Regulations on the Justice Laws Website ↗
Made under Canadian Environmental Protection Act, 1999, S.C. 1999, c. 33.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.