Multi-Sector Air Pollutants Regulations, SOR/2016-151
Section 26.1
Common stack
Cite as Multi-Sector Air Pollutants Regulations, SOR/2016-151, s. 26.1 · current to January 19, 2026 · regulation last amended January 1, 2026
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) A stack test or CEMS test at a common stack may be used to determine the NOx emission intensity for all of the boilers and heaters that share the common stack and are operating during the test.
(2) For the purposes of sections 34 and 36, if the only devices that share a common stack and are operating during a stack test or CEMS test are boilers or heaters, the result of that test applies when determining the NOx emission intensity of each of those boilers or heaters.
(3) For the purposes of sections 34 and 36, if a boiler or heater shares a common stack with a device to which this Part does not apply and that is operating during the test, the NOx emission intensity of that boiler or heater is determined by the formula(ΣrQr × Eout + ΣuQu × Eout − ΣuQu × Eu) ÷ ΣrQrwhereQris the energy, expressed in GJ, of the fuel combusted during the test by the rth boiler or heater;Eoutis the NOx emission intensity measured during the test, expressed in g/GJ;Quis the energy, expressed in GJ, of the fuel combusted during the test by the uth device;Euis the manufacturer’s guaranteed NOx emission intensity value, expressed in g/GJ for the uth device or, if the manufacturer has not provided such a guarantee, 26 g/GJ;ris the rth boiler or heater to which this Part applies that is operating at the common stack during the test, where r goes from 1 to n and n is the number of boilers or heaters that meet those criteria; anduis the uth device to which this Part does not apply that is operating at the common stack during the test, where u goes from 1 to n and n is the number of devices that meet those criteria.
(4) For greater certainty, if subsection (2) or (3) applies with respect to section 34, the stack test or CEMS test must have been conducted during the reference period described in subsection 34(1).
(5) For the purposes of sections 33 and 38, the NOx emission intensity of a boiler or heater that shares a common stack with any other device is deemed not to exceed the applicable limit set out in section 6, 7, 9 to 11, 13 or 14 if the NOx emission intensity of the common stack does not exceed the limit that is determined by the formula(Σj(Qj × Lj) + Σk(Qk × Ck) + Σu(Qu × Eu)) ÷ (ΣjQj + ΣkQk + ΣuQu)whereQjis the energy, expressed in GJ, of the fuel combusted during the test by the jth boiler or heater;Ljis the NOx emission intensity limit, expressed in g/GJ, that applies to the jth boiler or heater;Qkis the energy, expressed in GJ, of the fuel combusted during the test by the kth boiler or heater;Ckis the classification NOx emission intensity, expressed in g/GJ, of the kth boiler or heater;Quis the energy, expressed in GJ, of the fuel combusted during the test by the uth device;Euis the manufacturer’s guaranteed NOx emission intensity value, expressed in g/GJ for the uth device or, if the manufacturer has not provided such a guarantee, 26 g/GJ;jis the jth boiler or heater to which this Part applies that is operating at the common stack during the test and that is required under this Part to meet a NOx emission intensity limit, where j goes from 1 to n and n is the number of boilers or heaters that meet those criteria;kis the kth boiler or heater to which this Part applies that is operating at the common stack during the test but that is not required under this Part to meet a NOx emission intensity limit, where k goes from 1 to n and n is the number of boilers or heaters that meet those criteria; anduis the uth device to which this Part does not apply that is operating at the common stack during the test, where u goes from 1 to n and n is the number of devices that meet those criteria.
(6) When a triggering event described in subsection 37(3) occurs with respect to a boiler or heater that shares a common stack with any other device, the NOx emission intensity of the boiler or heater is determined by the formula((ΣtQt + ΣuQu + ΣxQx) × Eout − ΣuQu × Eu − ΣxQx × Cx) ÷ ΣtQtwhereQtis the energy, expressed in GJ, of the fuel combusted during the test by the tth boiler or heater;Quis the energy, expressed in GJ, of the fuel combusted during the test by the uth device;Qxis the energy, expressed in GJ, of the fuel combusted during the test by the xth boiler or heater;Eoutis the NOx emission intensity measured during the test, expressed in g/GJ;Euis the manufacturer’s guaranteed NOx emission intensity value, expressed in g/GJ, for the uth device or, if the manufacturer has not provided such a guarantee, 26 g/GJ;Cxis the classification NOx emission intensity, expressed in g/GJ, of the xth boiler or heater;tis the tth boiler or heater to which this Part applies that underwent a triggering event and is, during the test, operating at the common stack, where t goes from 1 to n and n is the number of boilers or heaters that meet those criteria;uis the uth device to which this Part does not apply that is operating at the common stack during the test, where u goes from 1 to n and n is the number of devices that meet those criteria; andxis the xth boiler or heater to which this Part applies that did not undergo a triggering event and that is operating at the common stack during the test, where x goes from 1 to n and n is the number of boilers or heaters that meet those criteria.
(7) A responsible person for a boiler or heater who determines a NOx emission intensity in accordance with subsection (3), (5) or (6) must, on the Minister’s request, provide to the Minister any supporting data used to make that determination.
Read the Multi-Sector Air Pollutants Regulations on the Justice Laws Website ↗
Made under Canadian Environmental Protection Act, 1999, S.C. 1999, c. 33.