If a vehicle, crane or similar equipment is operated near a live power line and it is possible for any part of it or its load to make contact with the live power line, (a) a worker shall be stationed within view of the operator to warn him or her when any part of the equipment is approaching the minimum distance from the live power line; and (b) clearance shall be allowed for any changes in boom angle and for any swing of the hoisting cable and load. O. Reg. 67/93, s. 73.