CONSTRUCTION PROJECTS, O. Reg. 213/91

Section 84

Cite as CONSTRUCTION PROJECTS, O. Reg. 213/91, s. 84 · current to November 11, 2026 · consolidated from April 20, 2026 · read from e-Laws on November 16, 2026

The text

(1) Subject to subsection (2), an access ladder fixed in position, (a) shall be vertical; (b) shall have rest platforms at not more than nine metre intervals; (c) shall be offset at each rest platform; (d) where the ladder extends over five metres above grade, floor or landing, shall have a safety cage commencing not more than 2.2 metres above grade, floor or landing and continuing at least 90 centimetres above the top landing with openings to permit access by a worker to rest platforms or to the top landing; (e) shall have side rails that extend 90 centimetres above the landing; (f) shall have rungs that are at least 15 centimetres from the wall and spaced at regular intervals; (g) shall have an adequate landing surface that is clear of obstructions at the top and bottom of the ladder for access and egress; (h) shall be free from defective or loose rungs; and (i) shall not be used in an elevator shaft or a similar hoisting area when the shaft or area is being used for hoisting. O. Reg. 631/94, s. 2; O. Reg. 345/15, s. 14 (1, 2). (2) Clauses (1) (b), (c) and (d) do not apply to any access ladder on a tower, water tank, chimney or similar structure that has a safety device that will provide protection should a worker using the ladder fall. O. Reg. 345/15, s. 14 (3). 85., 86. Revoked: O. Reg. 145/00, s. 24.
Read the CONSTRUCTION PROJECTS on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.