CONSTRUCTION PROJECTS, O. Reg. 213/91

Section 142.02

Cite as CONSTRUCTION PROJECTS, O. Reg. 213/91, s. 142.02 · current to November 11, 2026 · consolidated from April 20, 2026 · read from e-Laws on November 16, 2026

The text

(1) All wire rope terminations of the suspension line of a suspended work platform system or boatswain’s chair, including swaged socket and poured socket terminations, spliced eye terminations and turnback eye terminations shall, after installation onto the wire rope and prior to being used for the first time, be tested, (a) in accordance with the recommendations of the manufacturer of the wire rope or termination; and (b) to no more than 50 per cent of the wire rope’s nominal or minimum rated breaking strength. O. Reg. 242/16, s. 11. (2) While the suspended work platform system or boatswain’s chair is at the project and the termination remains in service, an employer shall keep at the project, and make available to an inspector on request, a record of the tests described in subsection (1). O. Reg. 242/16, s. 11. (3) The wire rope termination of a suspension line shall be protected from contact with the line’s hoisting device. O. Reg. 242/16, s. 11.
Read the CONSTRUCTION PROJECTS on e-Laws ↗