MINES AND MINING PLANTS, R.R.O. 1990, Reg. 854
Section 200
Cite as MINES AND MINING PLANTS, R.R.O. 1990, Reg. 854, s. 200 · current to November 11, 2026 · consolidated from July 1, 2025 · read from e-Laws on November 16, 2026
The text
(1) A reciprocating type air compressor driven by a prime mover exceeding thirty kilowatts, that is lubricated by oil and discharges to a closed system over 100 kilopascals, shall have,
(a) a temperature-indicating device installed at the high-pressure discharge pipe; and
(b) the normal operating temperature marked on the device. R.R.O. 1990, Reg. 854, s. 200 (1).
(2) The discharge air temperature shall be,
(a) read at least once every operating shift; and
(b) recorded in a compressor log book. R.R.O. 1990, Reg. 854, s. 200 (2).
Read the MINES AND MINING PLANTS on e-Laws ↗
Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.