MINES AND MINING PLANTS, R.R.O. 1990, Reg. 854

Section 199

Cite as MINES AND MINING PLANTS, R.R.O. 1990, Reg. 854, s. 199 · current to November 11, 2026 · consolidated from July 1, 2025 · read from e-Laws on November 16, 2026

The text

(1) An air compressor driven by a prime mover exceeding twenty-five kilowatts when installed in an underground mine shall be, (a) designed and installed so as to minimize the hazard of fire or explosion due to the accumulation of carbonaceous materials in the air system; (b) provided with protective devices that prevent its operation if, (i) the temperature of the air at the discharge line is in excess of normal, (ii) the temperature of the compressor cooling water and cooling air is in excess of normal, or (iii) the flow and pressure of compressor lubricating oil is below normal; (c) provided with an alarm that, (i) is audible and visible to the worker in charge of the compressor, (ii) operates when a device as prescribed in clause (b) is activated, (iii) operates as long as the conditions exist that cause a device as prescribed in clause (1) (b) to operate. R.R.O. 1990, Reg. 854, s. 199 (1). (2) No protective device prescribed in clause (b) shall be, (a) capable of automatically restarting the compressor; and (b) used unless tested and found to function properly. R.R.O. 1990, Reg. 854, s. 199 (2).
Read the MINES AND MINING PLANTS on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.