MINES AND MINING PLANTS, R.R.O. 1990, Reg. 854

Section 186

Cite as MINES AND MINING PLANTS, R.R.O. 1990, Reg. 854, s. 186 · current to November 11, 2026 · consolidated from July 1, 2025 · read from e-Laws on November 16, 2026

The text

(1) Subject to subsection (10), no elevator shall be put into service without an engineer giving written statement to the owner setting out, (a) the location of the elevator; (b) the maximum loading of number of persons and material that may be carried by the elevator when it is installed, maintained and operated in compliance with this Regulation; (c) that the elevator is designed and manufactured in accordance with appropriate engineering standards and installed where it is to be put into service in compliance with good engineering practice. O. Reg. 272/97, s. 33 (1); O. Reg. 373/22, s. 7. (2) Subsection (1) does not apply to an elevator that is operated for testing purposes. O. Reg. 272/97, s. 33 (1). (3) The owner shall ensure that a copy of the statement is posted at the mine site in a location readily visible to workers and that a copy is given to the joint health and safety committee or the health and safety representative, if any. O. Reg. 236/99, s. 5 (1). (4) The maximum loading set out in the statement required under subsection (1) or a permit referred to in subsection (10) shall not be exceeded. O. Reg. 272/97, s. 33 (1). (5) An elevator installation shall meet the following standard: 1. If it was installed before October 15, 1991, CSA Standard B44-1975, “Safety Code for Elevators, Dumbwaiters, Escalators and Moving Walks”. 2. If it was installed on or after October 15, 1991 and before April 23, 1999, CSA Standard B44-M90, “Safety Code for Elevators”. 3. If it was installed on or after April 23, 1999 and before October 1, 2007, CSA Standard B44-94, “Safety Code for Elevators”. 4. If it was installed on or after October 1, 2007, CSA Standard B44-00, “Safety Code for Elevators”. O. Reg. 84/07, s. 13; O. Reg. 34/14, s. 10. (6) Each component that may affect the safe operation of an elevator shall be examined and tested by a competent person before an elevator is initially used and thereafter at intervals not exceeding one month. R.R.O. 1990, Reg. 854, s. 186 (6). (7) A log book shall be kept in which the date, findings and name of the competent persons performing the examinations and tests prescribed in subsection (6) shall be recorded. R.R.O. 1990, Reg. 854, s. 186 (7). (8) In addition to the standards required to be met under subsection (5), an elevator shall, (a) have a safe means of access to the machinery room which access shall be located outside the hoistway; (b) not have hoisting or balance ropes that are spliced; (c) have the entry to the machinery room restricted to authorized persons; (d) have a means by which a person stranded in an elevator can alarm persons outside the elevator when the elevator is operated on automatic control; and (e) have its controls and machine parts protected against physical damage, moisture, dust or extreme temperatures. R.R.O. 1990, Reg. 854, s. 186 (8). (9) The machinery room of the elevator shall be kept clean and contain only those materials required for the elevator. R.R.O. 1990, Reg. 854, s. 186 (9). (10) Subsections (1) and (3) do not apply to an elevator being operated under a permit issued by the Ministry of Labour before August 16, 1997. O. Reg. 272/97, s. 33 (2).
Read the MINES AND MINING PLANTS on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.