(1) In an underground mine with trolley lines installed underground, the owner shall ensure that the requirements of this section are met. O. Reg. 779/94, s. 5.
(2) The lines must be designed to have a nominal voltage less than 1,200 volts and operated with a nominal voltage less than 1,200 volts. O. Reg. 779/94, s. 5.
(3) The lines must have ground fault protection if they use alternating current. O. Reg. 779/94, s. 5.
(4) If the operating voltage of the lines is greater than 300 volts, there must be,
(a) lighting or reflectors sufficient to indicate the location of the lines; and
(b) warning signs installed at points of access to the lines. O. Reg. 779/94, s. 5.
(5) Trolley lines of the bare conductor type must be protected by guards made of insulating materials. O. Reg. 779/94, s. 5.
(6) The guards must extend at least 75 millimetres below the lowest point of the trolley line and must be placed not more than 150 millimetres from the nearest line. O. Reg. 779/94, s. 5.
(7) Despite subsection (5), guards are not required on trolley lines of the bare conductor type that use alternating current if the trolley lines have ground fault protection that prevents a worker from being exposed to an electrical current sufficient to cause ventricular fibrillation. O. Reg. 779/94, s. 5.
(8) Trolley lines of the bare conductor type that are installed underground after December 31, 1994 must be located,
(a) at least 2.4 metres above grade, if the operating voltage is 300 volts or less;
(b) at least 2.7 metres above grade, if the operating voltage is more than 300 volts but less than 750 volts;
(c) at least 4.0 metres above grade, if the operating voltage is 750 volts or more. O. Reg. 779/94, s. 5.
(9) Trolley lines of the busway conductor type that are installed underground after December 31, 1994 must be located at least 2.4 metres above grade. O. Reg. 779/94, s. 5.
(10) Subsections (8) and (9) do not apply with respect to trolley lines that are an extension of a trolley line system,
(a) if the system is installed before January 1, 1995;
(b) if the system has an operating voltage of 300 volts or less; and
(c) if the extension is located at least 1.8 metres above grade. O. Reg. 779/94, s. 5.
(11) The employer shall establish written procedures to require all necessary precautions to work safely around trolley lines. O. Reg. 486/99, s. 12.