MINES AND MINING PLANTS, R.R.O. 1990, Reg. 854

Section 159

Cite as MINES AND MINING PLANTS, R.R.O. 1990, Reg. 854, s. 159 · current to November 11, 2026 · consolidated from July 1, 2025 · read from e-Laws on November 16, 2026

The text

(1) Electrical work shall not be performed on energized equipment except where, (a) de-energizing the equipment, (i) would increase or introduce additional hazards, or (ii) is not feasible due to equipment design or operational limitations; (b) equipment and personal protective devices and clothing that are appropriate to the work are provided and used; (c) the employer has established written measures and procedures for energized work to protect the health and safety of workers; (d) no hazard from explosive or flammable materials exists; and (e) all necessary precautions to work safely are taken. O. Reg. 265/15, s. 8. (2) Except as provided for in subsection (1), no object shall be brought closer than the distance specified in Column 2 of the following Table to an exposed, energized overhead electric supply line of the voltage specified in Column 1: TABLE Column 1 Voltage of Powerline | Column 2 Minimum Distance 300 to 150,000 volts | 3 Metres 150,000 to 250,000 volts | 4.5 Metres Over 250,000 volts | 6 Metres (3) Precautions to guard workers against injury by moving or energized parts shall be taken before maintenance, repair or adjustment work is performed on a machine that is energized. R.R.O. 1990, Reg. 854, s. 159 (3). (4) When located less than 1.5 metres measured in a horizontal plane or 2.5 metres measured in a vertical plane from a walkway or landing, any bare part of electrical equipment energized in excess of 150 volts DC or 50 volts AC shall be guarded. R.R.O. 1990, Reg. 854, s. 159 (4). (5) Machines that have movable or extendable booms must not be operated in close proximity to energized electrical supply lines unless, (a) they are operated in accordance with subsection (1); or (b) the operator of the machine has been authorized to perform such work and, (i) there is a clearance between any part of the machine and the energized line that is more than the greater of, (A) one-half the maximum horizontal reach of the boom, or (B) the distance determined under subsection (2), (ii) the lines are disconnected and grounded, (iii) the machine is a railroad crane operating on railroad tracks and the supply line is energized to less than 750 volts direct current, or (iv) the supply lines are guarded against contact by any part of the machine or its load. O. Reg. 60/94, s. 7. (6) Subsections (2) to (5) apply only with respect to electrical lines installed on the surface and electrical equipment used on the surface. O. Reg. 486/99, s. 6.
Read the MINES AND MINING PLANTS on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.