MINES AND MINING PLANTS, R.R.O. 1990, Reg. 854

Section 150

Cite as MINES AND MINING PLANTS, R.R.O. 1990, Reg. 854, s. 150 · current to November 11, 2026 · consolidated from July 1, 2025 · read from e-Laws on November 16, 2026

The text

(1) Where the source of current is a portable direct current battery or blasting machine the firing cables or wires shall, (a) not be connected to the source of current until, (i) the workplace to be affected by the blasting operation has been cleared of persons, and (ii) immediately prior to blasting; and (b) be disconnected and short-circuited immediately after the blast has been fired. R.R.O. 1990, Reg. 854, s. 150 (1). (2) A blasting machine shall, (a) be of a type and design specifically manufactured for the purpose; (b) be kept in good mechanical and electrical condition; (c) be tested regularly using methods specified by the manufacturer; (d) be tested before any blasts that may require the maximum output of the machine; (e) be clearly marked with the capacity of the machine; and (f) not be used in excess of its rated capacity. R.R.O. 1990, Reg. 854, s. 150 (2). (3) A portable direct current battery shall be of a type and design specifically manufactured for the purpose. O. Reg. 265/15, s. 6.
Read the MINES AND MINING PLANTS on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.