MINES AND MINING PLANTS, R.R.O. 1990, Reg. 854
Section 149
Cite as MINES AND MINING PLANTS, R.R.O. 1990, Reg. 854, s. 149 · current to November 11, 2026 · consolidated from July 1, 2025 · read from e-Laws on November 16, 2026
The text
When blasting by means of electricity,
(a) where balanced circuits are required, each circuit shall be tested before firing with a suitable galvanometer or other similar suitable instrument;
(b) where electric blasting caps are used,
(i) the protective shunt shall not be removed from the leg wire until connections are made,
(ii) the leg wire shall not be shortened to less than one metre,
(iii) the firing cables leading to the face or faces shall be short-circuited while the leads from the blasting caps are being connected to each other and to the firing cables,
(iv) the short-circuit prescribed in subclause (iii) shall not be removed until all workers have left the workplaces to be affected by the blasting operation, and
(v) the short-circuit prescribed in subclause (iii) shall be located so that a premature explosion will be harmless to the worker opening the short-circuit; and
(c) before any person returns to the workplace affected by the blasting operation,
(i) the firing cables shall be removed from the battery, blasting machine or other source of electricity and shall be short-circuited, and
(ii) the blasting switch shall be locked in the open position. R.R.O. 1990, Reg. 854, s. 149.