AIR POLLUTION — DISCHARGE OF SULPHUR DIOXIDE FROM PETROLEUM FACILITIES, O. Reg. 88/22
Section 15
Sulphur recovery unit without incinerator, measuring oxygen, total reduced sulphur limit
Cite as AIR POLLUTION — DISCHARGE OF SULPHUR DIOXIDE FROM PETROLEUM FACILITIES, O. Reg. 88/22, s. 15 · current to November 11, 2026 · consolidated from February 25, 2022 · read from e-Laws on November 16, 2026
The text
A person shall not discharge or cause or permit the discharge of total reduced sulphur into the air from a sulphur recovery unit in respect of which the criteria set out in subsection 5 (1) are met and that is not associated with an incinerator at a petroleum facility if the concentration of total reduced sulphur, measured as a concentration of sulphur dioxide, in parts per million by volume, at a measurement point in respect of the sulphur recovery unit exceeds the concentration determined by the following formula, averaged over any 12-hour period:
A × 1.2 × (-0.038 × B2 + 11.53 × B + 25.6)
where,
“A” is,
(a) 1, if the sulphur recovery unit has a design production capacity of greater than 20 tonnes per day, or
(b) 10, if the sulphur recovery unit has a design production capacity of 20 tonnes per day or less, and
“B” is,
(a) the concentration of oxygen gas in the air/oxygen mixture supplied to the Claus burner, as a per cent by volume, on a dry basis, averaged over a 12-hour period, or
(b) 20.9, during any period when ambient air is being supplied to the Claus burner instead of the air/oxygen mixture.
Read the AIR POLLUTION — DISCHARGE OF SULPHUR DIOXIDE FROM PETROLEUM FACILITIES on e-Laws ↗
Made under Environmental Protection Act, R.S.O. 1990, c. E.19.