GREENHOUSE NUTRIENT FEEDWATER, O. Reg. 300/14
Section 50
Construction and expansion, if operation is subject to GNF strategy, GNF plan
Cite as GREENHOUSE NUTRIENT FEEDWATER, O. Reg. 300/14, s. 50 · current to November 11, 2026 · consolidated from April 1, 2024 · read from e-Laws on November 16, 2026
The text
(1) No person shall construct or expand a permanent GNF storage facility at an agricultural operation that is subject to a GNF strategy or a GNF plan unless the following conditions are met:
1. The facility must have a surface channel or depression that conducts liquids away from the facility and that is at least 50 metres long to the top of the bank of the nearest surface water or tile inlet.
2. No construction or expansion of the facility shall be carried out within the one in 100 year flood lines established by the municipality or the conservation authority having jurisdiction over the location of the facility if the municipality or the conservation authority has established such flood lines, unless a permit has been issued with respect to the facility in accordance with section 28.1 or 28.1.1 of the Conservation Authorities Act.
3. If the maximum liquid level is either partially or wholly located above the surface of the soil in a permanent GNF storage facility that is made of a material other than rigid plastic,
i. the load factor, αL, for liquid loads must be 1.5 or another value that a professional engineer is satisfied should be used,
ii. a professional engineer must specify that the storage and landscape features around the facility are adequate to ensure that a secondary containment system is not required, or
iii. the above grade portion of the facility must have a secondary containment system with a capacity equivalent to 110 per cent of the above ground portion of the facility.
4. The person who constructs or expands the permanent GNF storage facility shall use an importance factor of 1.0. O. Reg. 300/14, s. 50 (1); O. Reg. 234/15, s. 19; O. Reg. 48/24, s. 1.
(2) For the purposes of subsection (1),
(a) the reference to the load factor, αL, is a reference to that term as defined in clause 4.1.3.1. (1) (c) of Part 4 of Ontario Regulation 403/97 (Building Code) made under the Building Code Act, 1992, as it read on December 30, 2006; and
(b) the reference to the importance factor is a reference to that term as defined in Part 4 of Ontario Regulation 403/97, as it read on December 30, 2006. O. Reg. 300/14, s. 50 (2).
Read the GREENHOUSE NUTRIENT FEEDWATER on e-Laws ↗
Made under Nutrient Management Act, 2002, S.O. 2002, c. 4.