REGISTRATIONS UNDER PART II.2 OF THE ACT — PRINTING, O. Reg. 349/12
Section 2
Measurement of distance
Cite as REGISTRATIONS UNDER PART II.2 OF THE ACT — PRINTING, O. Reg. 349/12, s. 2 · current to November 11, 2026 · consolidated from February 3, 2017 · read from e-Laws on November 16, 2026
The text
For the purposes of this Regulation, a distance described in Column 1 of the following Table shall be measured horizontally and in accordance with the rules set out opposite the distance in Column 2 of the Table:
Table
Item | Column 1 Distance | Column 2 Rules
1. | Between the exterior wall of a building and the property boundary of a noise receptor. | 1. Measure from the point that is located on the exterior wall and closest to the property boundary of the noise receptor. 2. Measure to the point that is located on the property boundary of the noise receptor and closest to the point from which the measurement is made.
2. | Between a noise generating equipment unit and the property boundary of a noise receptor. | 1. Measure from the point that is located on the edge of the unit and closest to the property boundary of the noise receptor. 2. Measure to the point that is located on the property boundary of the noise receptor and closest to the point from which the measurement is made.
3. | Between an exhaust stack and the property boundary of a noise receptor. | 1. Measure from the point that is located at the centre of the stack at the point of discharge. 2. Measure to the point that is located on the property boundary of the noise receptor and closest to the point from which the measurement is made.
4. | Between the centre of a building and the property boundary of a printing facility. | 1. Measure from the point that is located at the centre of the smallest rectangular area that can be measured surrounding the building at ground level and, if there is more than one rectangular area that meets this description, the centre of any one of those rectangular areas. 2. Measure to the point that is located on the property boundary of the printing facility and closest to the point from which the measurement is made.
Read the REGISTRATIONS UNDER PART II.2 OF THE ACT — PRINTING on e-Laws ↗
Made under Environmental Protection Act, R.S.O. 1990, c. E.19.