REGISTRATIONS UNDER PART II.2 OF THE ACT — AUTOMOTIVE REFINISHING, O. Reg. 347/12
Section 2
Prescribed activities, s. 20.21 (1) of the Act
Cite as REGISTRATIONS UNDER PART II.2 OF THE ACT — AUTOMOTIVE REFINISHING, O. Reg. 347/12, s. 2 · current to November 11, 2026 · consolidated from March 6, 2015 · read from e-Laws on November 16, 2026
The text
(1) Subject to subsections (3) and (4), the following are prescribed activities for the purposes of subsection 20.21 (1) of the Act:
1. The use, operation, construction, alteration, extension or replacement of any structure, equipment, apparatus, mechanism or thing that is used for automotive refinishing at an automotive refinishing facility that meets the criteria set out in subsection (2) and that may discharge or from which may be discharged a contaminant into any part of the natural environment other than water.
2. The alteration of a process or rate of production with respect to any structure, equipment, apparatus, mechanism, or thing that is used for automotive refinishing at an automotive refinishing facility that meets the criteria set out in subsection (2) if the alteration may result in,
i. a contaminant being discharged into any part of the natural environment other than water, or
ii. the rate or manner of discharge of a contaminant into any part of the natural environment other than water being altered. O. Reg. 347/12, s. 2 (1).
(2) The criteria referred to in subsection (1) with respect to an automotive refinishing facility are the following:
1. If the facility is located in a building that is wholly occupied by the facility, the facility has at least one and not more than three spray booths and does not exceed a facility-wide coating application rate of six litres per hour under normal operation.
2. If the facility is located in a building that contains more than one unit, at least one of which is not occupied by the facility, the facility has only one spray booth and does not exceed a facility-wide coating application rate of two litres per hour under normal operation.
3. For each of the facility’s spray booths, the distance, measured horizontally, between the following two points is not less than the distance set out in Column 2 of Table 1 of this subsection for the facility’s facility-wide coating application rate under normal operation set out opposite in Column 1 of that Table:
i. The centre of the spray booth’s exhaust stack.
ii. The point located on the property boundary of the facility and closest to the spray booth’s exhaust stack.
4. If the facility contains one or more spray booths that are served by fans that are indoors, for each of those spray booths one of the following criteria is met:
i. The distance, measured horizontally, between the following two points is not less than the distance set out in Column 2 of Table 2 of this subsection for the number of spray booths in the facility served by indoor fans set out opposite in Column 1 of that Table:
A. The centre of the spray booth’s exhaust stack.
B. The point located on the property boundary of any noise receptor and closest to the spray booth’s exhaust stack.
ii. Acoustic barriers that have a density of at least 12 kilograms per square metre are installed that block the direct line of sight between the exhaust stack of every spray booth in the facility served by indoor fans and every noise receptor in respect of which the distance, measured horizontally, between the following two points is less than the distance set out in Column 2 of Table 2 of this subsection for the number of spray booths in the facility served by indoor fans set out opposite in Column 1 of that Table:
A. The centre of the spray booth’s exhaust stack.
B. The point located on the property boundary of any noise receptor and closest to the spray booth’s exhaust stack.
5. If the facility contains one or more spray booths that are served by fans that are outdoors, for each of the outdoor fans one of the following criteria is met:
i. The distance, measured horizontally, between the following two points is not less than the distance set out in Column 2 of Table 3 of this subsection for the number of spray booths in the facility served by outdoor fans set out opposite in Column 1 of that Table:
A. The outdoor fan.
B. The point located on the property boundary of any noise receptor and closest to the outdoor fan.
ii. Acoustic barriers that have a density of at least 12 kilograms per square metre are installed that block the direct line of sight between the outdoor fan and every noise receptor in respect of which the distance, measured horizontally, between the following two points is less than the distance set out in Column 2 of Table 3 of this subsection for the number of spray booths in the facility served by outdoor fans set out opposite in Column 1 of that Table:
A. The outdoor fan.
B. The point located on the property boundary of any noise receptor and closest to the outdoor fan.
6. The wastewater from the facility, if any,
i. is transferred to a waste management system,
A. that is subject to an environmental compliance approval, or
B. in respect of which an activity has been registered for the purposes of subsection 20.21 (1) of the Act,
ii. is discharged to a sewage works that is subject to an environmental compliance approval, or
iii. is discharged to a municipal sanitary sewer.
7. If the facility is located in an area of development control within the Niagara Escarpment Planning Area, any development permit required under section 24 of the Niagara Escarpment Planning and Development Act in respect of the facility has been issued and the requirements of this Regulation are not in conflict with any conditions of the permit.
TABLE 1 DISTANCE FROM FACILITY’S PROPERTY BOUNDARY
Item | Column 1 Facility-wide coating application rate under normal operation in litres per hour | Column 2 Distance in metres
1. | ≤ 2 | 0
2. | > 2 to ≤ 3 | 20
3. | > 3 to ≤ 4 | 38
4. | > 4 to ≤ 5 | 55
5. | > 5 to ≤ 6 | 75
TABLE 2 DISTANCE FROM NOISE RECEPTOR’S PROPERTY BOUNDARY — INDOOR FANS
Item | Column 1 Number of spray booths in the facility served by indoor fans | Column 2 Distance in metres
1. | 1 | 40
2. | 2 | 55
3. | 3 | 75
TABLE 3 DISTANCE FROM NOISE RECEPTOR’S PROPERTY BOUNDARY — OUTDOOR FANS
Item | Column 1 Number of spray booths in the facility served by outdoor fans | Column 2 Distance in metres
1. | 1 | 60
2. | 2 | 85
3. | 3 | 120
(2.1) For the purposes of paragraphs 4 and 5 of subsection (2), a noise receptor does not include any building or campground that is located on the property on which the automotive refinishing facility is or will be situated. O. Reg. 43/15, s. 1 (3).
(3) This section does not apply in respect of any activities relating to the construction of a structure, equipment, apparatus, mechanism or thing that is used in an automotive refinishing facility for the purposes of automotive refinishing that are carried out at a site other than the automotive refinishing facility. O. Reg. 347/12, s. 2 (3).
(4) This section does not apply in respect of activities engaged in at an automotive refinishing facility that meets any of the following criteria:
1. The facility manufactures motor vehicles or motor vehicle parts.
2. The facility is primarily engaged in the replacement and repair of glass with respect to motor vehicles.
3. The facility is primarily engaged in the repair of mechanical or electrical components of motor vehicles.
4. The facility is a mobile refinishing facility.
5. The facility controls the emissions from a spray booth using water wash filtration. O. Reg. 347/12, s. 2 (4).
Read the REGISTRATIONS UNDER PART II.2 OF THE ACT — AUTOMOTIVE REFINISHING on e-Laws ↗
Made under Environmental Protection Act, R.S.O. 1990, c. E.19.