renewable energy approvals under Part V.0.1 of the Act, O. Reg. 359/09
Section 6
Wind facilities
Cite as renewable energy approvals under Part V.0.1 of the Act, O. Reg. 359/09, s. 6 · current to November 11, 2026 · consolidated from July 28, 2026 · read from e-Laws on November 16, 2026
The text
(1) A wind facility is a wind facility of a class set out in Column 1 of the Table to this section if,
(a) the wind turbines that form part of the facility are at a location set out opposite the class in Column 2 of the Table;
(b) the facility has a name plate capacity that meets the criteria set out opposite the class in Column 3 of the Table; and
(c) the other specifications in Column 4 of the Table are met. O. Reg. 359/09, s. 6 (1); O. Reg. 97/16, s. 2 (1).
(2) In this Regulation, a reference to a Class 1, 2, 3, 4 or 5 wind facility is a reference to a wind facility of that class. O. Reg. 359/09, s. 6 (2).
(3) For the purposes of this Regulation, two or more wind facilities that each meet the criteria set out for the same class of wind facility in subsection (1) shall be deemed to be a single wind facility in accordance with the following rules if the facilities are to function together as an integrated or aggregated system for generating electricity:
1. Two or more Class 1 wind facilities that have a combined name plate capacity of greater than 3 kW are deemed to be,
i. a Class 2 wind facility, if the combined name plate capacity is less than 50 kW, or
ii. a Class 3 wind facility, if the combined name plate capacity is greater than or equal to 50 kW.
2. Two or more Class 2 wind facilities are deemed to be a single Class 2 wind facility.
3. Two or more Class 3 wind facilities are deemed to be a single Class 3 wind facility.
4. Two or more Class 4 wind facilities are be deemed to be a single Class 4 wind facility.
5. Two or more Class 5 wind facilities are deemed to be a single Class 5 wind facility. O. Reg. 359/09, s. 6 (3).
Table
Item | Column 1 Class of wind facility | Column 2 Location of wind turbines | Column 3 Name plate capacity of the facility (expressed in kW) | Column 4 Other specifications
1. | Class 1 | At a location where no part of a wind turbine is located in direct contact with surface water other than in a wetland. | ≤ 3 | None.
2. | Class 2 | At a location where no part of a wind turbine is located in direct contact with surface water other than in a wetland. | > 3 and < 50 | None.
3. | Class 3 | At a location where no part of a wind turbine is located in direct contact with surface water other than in a wetland. | ≥ 50 | Greatest sound power level (expressed in dBA) is < 102; greatest height (expressed in metres) of any wind turbine that forms part of the facility, excluding length of any blades, is < 70.
4. | Class 4 | At a location where no part of a wind turbine is located in direct contact with surface water other than in a wetland. | ≥ 50 | One of the following: 1. Greatest sound power level (expressed in dBA) is ≥ 102. 2. Greatest sound power level (expressed in dBA) is < 102; greatest height (expressed in metres) of any wind turbine that forms part of the facility, excluding length of any blades, is ≥ 70.
5. | Class 5 | At a location where one or more parts of a wind turbine is located in direct contact with surface water other than in a wetland. | Any. | None.
Read the renewable energy approvals under Part V.0.1 of the Act on e-Laws ↗
Made under Environmental Protection Act, R.S.O. 1990, c. E.19.