renewable energy approvals under Part V.0.1 of the Act, O. Reg. 359/09

Section 50

Class 3 anaerobic digestion facilities

Cite as renewable energy approvals under Part V.0.1 of the Act, O. Reg. 359/09, s. 50 · current to November 11, 2026 · consolidated from July 28, 2026 · read from e-Laws on November 16, 2026

The text

(1) No person shall construct, install or expand a Class 3 anaerobic digestion facility unless the facility is, (a) designed to be equipped with, (i) an anaerobic digester that has a gas storage cover with a design permeability of less than 500 cm3/m2/day/bar, and (ii) a high efficiency flare system; or (b) designed to minimize the discharge of odour to at least the same extent as if the facility had the characteristics set out in clause (a). O. Reg. 359/09, s. 50 (1). (2) If, in the absence of subsection 47.3 (2) of the Act, an environmental compliance approval would be required under the Act to engage in an activity mentioned in subsection 27 (1) of the Act at a Class 3 anaerobic digestion facility, the applicant shall submit, as part of the application for the issue of a renewable energy approval, a financial assurance estimate related to the cost of the removal and disposal of waste from the project location. O. Reg. 359/09, s. 50 (2); O. Reg. 231/11, s. 2. (3) The financial assurance estimate mentioned in subsection (2) shall be prepared in accordance with the methodology in the Financial Assurance Guideline. O. Reg. 359/09, s. 50 (3).
Read the renewable energy approvals under Part V.0.1 of the Act on e-Laws ↗

Made under Environmental Protection Act, R.S.O. 1990, c. E.19.