renewable energy approvals under Part V.0.1 of the Act, O. Reg. 359/09
Section 4
Solar facilities
Cite as renewable energy approvals under Part V.0.1 of the Act, O. Reg. 359/09, s. 4 · current to November 11, 2026 · consolidated from July 28, 2026 · read from e-Laws on November 16, 2026
The text
(1) A solar facility is a solar facility of a class set out in Column 1 of the Table to this section if,
(a) the solar photovoltaic collector panels or devices that form part of the facility are at a location set out opposite the class in Column 2 of the Table; and
(b) the facility has a name plate capacity that meets the criteria set out opposite the class in Column 3 of the Table. O. Reg. 359/09, s. 4 (1).
(2) In this Regulation, a reference to a Class 1, 2 or 3 solar facility is a reference to a solar facility of that class. O. Reg. 359/09, s. 4 (2).
(3) For the purposes of this Regulation, two or more solar facilities that each meet the criteria set out for the same class of solar facility in subsection (1) shall be deemed to be a single solar facility in accordance with the following rules if the facilities are to function together as an integrated or aggregated system for generating electricity:
1. Two or more Class 1 solar facilities that have a combined name plate capacity of less than or equal to 10 kW are deemed to be a single Class 1 solar facility.
2. Two or more Class 1 solar facilities that have a combined name plate capacity of greater than 10 kW and whose solar photovoltaic collector panels or devices are not mounted on a roof or wall of a building are deemed to be a single Class 3 solar facility.
3. Two or more Class 3 solar facilities are deemed to be a single Class 3 solar facility. O. Reg. 359/09, s. 4 (3); O. Reg. 195/12, s. 2 (1).
Table
Item | Column 1 Class of solar facility | Column 2 Location of solar photovoltaic collector panels or devices | Column 3 Name plate capacity of solar facility (expressed in kW)
1. | Class 1 | At any location. | ≤ 10
2. | Class 2 | Mounted on the roof or wall of a building. | > 10
3. | Class 3 | At any location other than mounted on the roof or wall of a building. | > 10
Read the renewable energy approvals under Part V.0.1 of the Act on e-Laws ↗
Made under Environmental Protection Act, R.S.O. 1990, c. E.19.