fire code, O. Reg. 213/07
Section 9.8.3.2
Cite as fire code, O. Reg. 213/07, s. 9.8.3.2 · current to November 11, 2026 · consolidated from January 1, 2026 · read from e-Laws on November 16, 2026
The text
(1) Each residential unit shall be served by at least one means of escape consisting of a door that
(a) serves only that residential unit,
(b) opens directly to the exterior from that residential unit, and
(c) has direct access to ground level.
(2) Where a residential unit is served by only one means of escape, the flame-spread rating of interior wall and ceiling finishes of hallways and stairways leading to the means of escape shall not exceed 150.
(3) Doors within hallways and stairways referred in Sentence (2) are permitted to have a flame-spread rating of up to 200.