fire code, O. Reg. 213/07
Section 9.5.3.2
Cite as fire code, O. Reg. 213/07, s. 9.5.3.2 · current to November 11, 2026 · consolidated from January 1, 2026 · read from e-Laws on November 16, 2026
The text
(1) Each floor area shall be served by a minimum of two exits.
(2) A single exit from a basement, first or second floor is deemed to be in compliance with Sentence (1) where the building is not more than 3 storeys in building height and is not greater than 600 m2 in building area and
(a) the exit does not serve more than four dwelling units, or
(b) the exit does not serve more than 10 persons.
(3) Where a building is not more than 3 storeys in building height and not greater than 600 m2 in building area, alternative measures to Sentence (1) may be used if they are approved, and in the opinion of the Chief Fire Official, will provide protection for life safety similar to the protection provided by compliance with Sentence (1).
Stairway separations
Read the fire code on e-Laws ↗
Made under Fire Protection and Prevention Act, 1997, S.O. 1997, c. 4.