(1) During demolition, fire fighting access routes shall be maintained in accordance with Section 2.5. (2) Unobstructed access to fire hydrants, portable extinguishers and fire department connections for standpipe and sprinkler systems shall be maintained during demolition. (3) If a demolition site is fenced so as to prevent general entry, provision shall be made for access by fire department equipment and personnel. (4) Elevating devices shall be accessible for the use of firefighters for buildings under demolition that are more than 36 m in building height, measured between grade and the floor level of the top storey. Portable extinguishers