certification of drinking water system Operators and water quality analysts, O. Reg. 128/04
Schedule 1.3
Cite as certification of drinking water system Operators and water quality analysts, O. Reg. 128/04, Schedule 1.3 · current to November 11, 2026 · consolidated from December 3, 2021 · read from e-Laws on November 16, 2026
The text
SCHEDULE 1.3 Water TREATMENT SUBSYSTEMS (POINTS SYSTEM)
1. The number of points applicable to a water treatment subsystem is determined by applying the following rules and the Tables set out in this Schedule:
1. The number of points applicable to a water treatment subsystem based on the population it serves is 1 point for every 10,000 people, to a maximum of 10 points.
2. For every 4,500 cubic metres of flow at a water treatment subsystem, the number of points applicable to the subsystem is 1 point, up to a maximum of 10 points. The flow at the subsystem is the greater of the following:
i. The average daily design flow.
ii. The average daily flow in peak month.
3. The number of points applicable to a water treatment subsystem based on its water supply source is the following:
i. 3 points apply if the source is groundwater.
ii. 5 points apply if the source is surface water.
4. The number of points applicable to a water treatment subsystem with respect to bacteriological and biological laboratory control by subsystem personnel, as determined by applying Table 4 set out in this Schedule, is the greatest of the numbers set out in Column 2 of that Table that applies to the subsystem.
5. The number of points applicable to a water treatment subsystem with respect to chemical and physical laboratory control by subsystem personnel, as determined by applying Table 5 set out in this Schedule, is the greatest of the numbers set out in Column 2 of that Table that applies to the subsystem.
Table 1 Points based on raw water quality
Item | Column 1 Raw water quality | Column 2 Number of points
1. | Low variation in raw water quality and raw water quality is not subject to serious industrial waste pollution | 0
2. | Moderate variation in raw water quality and raw water quality is not subject to serious industrial waste pollution | 2
3. | High variation in raw water quality and raw water quality is not subject to serious industrial waste pollution | 5
4. | Raw water quality is subject to serious industrial waste pollution | 10
Table 2 Points based on processes
Item | Column 1 Process used | Column 2 Number of points
1. | Subsystem uses aeration, other than packed tower aeration | 2
2. | Subsystem uses packed tower aeration | 6
3. | Subsystem uses pH adjustment | 4
4. | Subsystem uses stability or corrosion control | 4
5. | Subsystem uses taste and odour control | 8
6. | Subsystem uses colour control | 4
7. | Subsystem uses iron or manganese removal | 10
8. | Subsystem uses ion exchange softening | 10
9. | Subsystem uses chemical precipitation softening | 20
10. | Subsystem uses coagulant addition | 4
11. | Subsystem uses flocculation | 6
12. | Subsystem uses sedimentation | 5
13. | Subsystem uses up flow clarification | 14
14. | Subsystem uses filtration | 10
15. | Subsystem uses fluoridation | 5
16. | Subsystem uses disinfection | 5
17. | Subsystem uses chlorine dioxide, chloramines or ozonation for disinfection | 5
18. | Subsystem uses other special processes | 15
19. | Subsystem has internal treatment of plant sludge | 6
Table 3 Points based on sludge/backwash water disposal
Item | Column 1 Sludge/backwash water disposal | Column 2 Number of points
1. | No disposal to raw water sources | 0
2. | Any disposal to raw water source | 2
3. | Any disposal to subsystem raw water | 5
Table 4 Points based on Bacteriological and biological laboratory control by subsystem personnel
Item | Column 1 Bacteriological and biological laboratory control by subsystem personnel | Column 2 Number of points
1. | Subsystem personnel perform bacteriological tests for non-regulatory purposes | 4
2. | Subsystem personnel do biological identification | 7
3. | Lab work is performed by an accredited laboratory | 0
Table 5 Points based on chemical and physical laboratory control by subsystem personnel
Item | Column 1 Chemical and physical laboratory control by subsystem personnel | Column 2 Number of points
1. | Subsystem personnel use colorimetric methods to do simple determinations such as pH or chlorine residual | 3
2. | Subsystem personnel do alkalinity or hardness determinations, titrations, jar tests, or similar tests | 5
3. | Subsystem personnel do determinations for operational parameters (e.g. aluminium) or perform advanced chemical testing beyond regulatory requirements | 7
4. | Subsystem personnel perform procedures using very sophisticated instrumentation, such as atomic absorption or gas chromatography | 10
Read the certification of drinking water system Operators and water quality analysts on e-Laws ↗
Made under Safe Drinking Water Act, 2002, S.O. 2002, c. 32.