SCHEDULE 12 MICROBIOLOGICAL SAMPLING AND TESTING
Municipal: Small Non-Residential Large Non-Residential
Non-Municipal: Seasonal Residential Small Non-Residential Large Non-Residential
Application
12-1. This Schedule applies to the following drinking water systems:
0.1 Large municipal non-residential systems.
1. Small municipal non-residential systems.
2. Non-municipal seasonal residential systems.
2.1 Large non-municipal non-residential systems.
3. Small non-municipal non-residential systems.
Distribution samples
12-2. (1) The owner of a drinking water system and the operating authority for the system shall ensure that,
(a) at least one distribution sample is taken every month, if the system provides treatment equipment in accordance with Schedule 2 and the equipment is operated in accordance with that Schedule; or
(b) at least one distribution sample is taken every two weeks, if clause (a) does not apply.
(2) If a non-municipal seasonal residential system supplies water to more than 100 service connections, the owner of the system and the operating authority for the system shall ensure that, for every 100 service connections, at least one distribution sample is taken every month, in addition to the samples required by subsection (1).
(3) The owner of the drinking water system and the operating authority for the system shall ensure that each of the samples taken under subsections (1) and (2) is tested for,
(a) Escherichia coli;
(b) total coliforms; and
(c) if subsection 2-5 (1) of Schedule 2 applies to the system, general bacteria population expressed as colony counts on a heterotrophic plate count.
(4)-(6) Revoked: O. Reg. 247/06, s. 23 (5).
(7) If a drinking water system uses point of entry treatment units, the samples taken under subsection (1) shall be taken from locations downstream of the point of entry treatment units and,
(a) in the case of a non-municipal seasonal residential system that serves a major residential development, the samples shall be taken on a rotational basis so that a sample is taken from a location downstream of each point of entry treatment unit at least once every 24 months; and
(b) in any other case, the samples shall be taken on a rotational basis so that, after a sample is taken from a location downstream of a particular point of entry treatment unit, another sample is not taken from a location downstream of that unit until samples have been taken from locations downstream of all the other point of entry treatment units.
(8) Revoked: O. Reg. 247/06, s. 23 (7).
Raw water samples
12-3. (1) If a drinking water system obtains water from a raw water supply that is ground water or a drinking water system is deemed under section 2 to obtain water from a raw water supply that is surface water, the owner of the system and the operating authority for the system shall ensure that a water sample is taken at least once every month from the raw water in each well that is supplying water to the system, before any treatment is applied to the water.
(2) Revoked: O. Reg. 247/06, s. 23 (8).
(3) The owner of the drinking water system and the operating authority for the system shall ensure that each of the samples taken under subsection (1) is tested for,
(a) Escherichia coli; and
(b) total coliforms.
Seven-day shutdowns, etc.
12-4. (1) Sections 12-2 and 12-3 do not apply to a large municipal non-residential system, small municipal non-residential system, large non-municipal non-residential system or small non-municipal non-residential system during a period of seven or more consecutive days when the system is not supplying water to any designated facilities or public facilities that are open.
(2) Sections 12-2 and 12-3 do not apply to a non-municipal seasonal residential system during a period of seven or more consecutive days when the system,
(a) is not supplying water to any designated facilities or public facilities that are open;
(b) is not supplying water to any major residential development; and
(c) is not supplying water to any trailer park or campground that has more than five service connections.
(3) If, pursuant to subsection (1) or (2), sections 12-2 and 12-3 do not apply to a drinking water system during a period of seven or more consecutive days, the owner of the system and the operating authority for the system shall ensure that no drinking water is supplied to a user of water after that period until samples have been taken and tested under sections 12-2 and 12-3 and the results of the tests have been received by the owner and the operating authority.
12-5. Revoked: O. Reg. 249/03, s. 17 (5).
12-6. Revoked: O. Reg. 253/05, s. 15 (4).